I/O classification: Analog output.
I/O points: 4.
I/O connections: Molex connector.
Power supply voltage: 24 VDC.
I/O specification: 0 to 5 V, 1 to 5 V, 0 to 10 V, -10 to 10 V.
Analog Input/Output Units Compatible with MULTIPLE I/O TERMINAL.
mounted or dismounted. (GT1-AD08MX, GT1-DA04MX)
8 or 4 inputs.
4 outputs.
High resolution of 1/6,000.
High conversion speed of 8 ms/8 points or 4 ms/4 points.
DIN track mounting.
Connector model Terminal Block Model.
classification: Power MOS FET relay output.
I/O points: 8 points.
Rated voltage: 24 VDC.
Relay coil rating: 24 VDC.
Applicable relay: G3DZ-2R6PL.
Ultra-miniature 8-point and 16-point,
Relay-mounted Terminals Ultra-compact.
(8-point models: 101 x 51 x 51 mm (W x H x D);
16-point models: 156 x 51 x 51 mm (W x H x D)),
Power MOS FET Relay and Relay models GT1-DA04MX.
DIN track mounting and screw mounting are available
GT1-DA04MX Input capacity: 16 points.
Rated current (ON current): 0.5 A/output, 4.0 A/common.
Internal I/O common: NPN.
Residual voltage: 1.2 V max. (0.5 ADC,
between each output terminal and the G terminal).
Leakage current: 0.1 mA max.
ON delay: 0.5 ms max.
OFF delay: 1.5 ms max.
Number of circuits per common: 16 points/common GT1-DA04MX.
Output indicators: LED display (yellow).
Isolation method: Photocoupler isolation.
I/O power supply method: Supply by I/O power supply.
Output device supply current: 100 mA/point.
Unit power supply current consumption: 80 mA max.
(for 20.4 to 26.4-VDC power supply voltage)
e-CON Connector insertion durability: 50 times.
Weight: 130 g max.
Expansion functions: No GT1-DA04MX.
Output handling for communications errors:
Select either hold or clear.
Short-circuit protection function: No.
Easy wiring using industry standard,
e-CON connectors.
Special wiring tool is not necessary.
Digital I/O terminal with industry,
standard e-CON connectors.
A common terminal is provided for,
each connector.
The I/O terminal and the sensors can,
be connected directly.
Input response time can be switched for,
high-speed processing.
Selectable node address setting methods:
setting with rotary,
switch and with tool software.
When setting the nodes wiith rotary switch,
setting is easy and node identification,
becomes possible for maintenance GT1-DA04MX. I/O classification: SSR.
I/O points: 8.
I/O connections: M3 terminal block.
Power supply voltage: 24 VDC.
I/O specification: --.
Relay Ouutput Unit Compatible with MULTIPLE I/O TERMINAL GT1-DA04MX.
8- and 16-point relay output models are available.
Equipped with 8-point SSRs.
DIN track mounting.