GRT1-DA2C CompoNet Communications Unit
OMRON GRT1-DA2C Manual And Instructions
GRT1-DA2C datasheetPDF datasheet
GRT1-DA2C REFERENCE MANUAL

OMRON GRT1-DA2C Product information and technical parameters:
Brand: OMRON
Name: CompoNet Communications Unit
Model: GRT1-DA2C
Name: Slice I/O Units; Analog I/O Units.
Specifications: Analog outputs (current).
Standards: CE, UC1, L.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on site.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error.

Input capacity: 16 points.
Internal I/O common: PNP.
ON voltage: 15 VDC min. (between each in,
put terminal and the G terminal).
OFF voltage: 5 VDC max. (between each in,
put terminal and the G terminal).
OFF current: 1.0 mA max.
Input current: 6.0 mA max./input (at 24-VDC),
3.0 mA min./input (at 17-VDC) GRT1-DA2C.
ON delay: 0.1 ms max.
OFF delay: 0.2 ms max.
Input filter value: Without filter, 0 GRT1-DA2C5 ms,
1 ms, 2 ms, 4 ms, 8 ms, 16 ms, 32 ms.
(Default setting: 1ms)
Number of circuits per common: 16 points/common.
Input indicators: LED display (yellow).
Isolation method: No isolation.
I/O power supply method: Supplied from unit power supply.
Input device supply current: 50 mA/point.
Unit power supply current consumption: 150 mA max GRT1-DA2C.
(for 20.4 to 26.4-VDC power supply voltage)
e-CON Connector insertion durability: 50 times.
Weight: 140 g max.
Expansion functions: No.
Short-circuit protection function: Available.
(Operates at 50 mA/point min.)
Easy wiring using industry standard,
e-CON connectors.
Special wiring tool is not necessary.
Digital I/O terminal with industry,
standard e-CON connectors GRT1-DA2C.
A common terminal is provided for,
each connector.
The I/O terminal and the sensors can,
be connected directly.
Input response time can be switched for,
high-speed processing.
Selectable node address setting methods:
setting with rotary,
switch and with tool software.
When setting the nodes with rotary switch,
setting is easy and node identification,
becomes possible for maintenance. Specifications: Outputs; PNP (+ common); 16 points.
I/O connections: MIL connector.
Rated internal circuit power supply voltage:
Supplied from the communications connector.
Rated I/O power supply voltage: 24 VDC.
Very Compact 16-/32-point Remote Terminals.
Used in combination with Interface,
Conversion Boards (e.g., D-Sub) to,
connect to a wide range of interfaces.
35 x 60 x 80 mm (W x D x H). Name: Three-tier Screw Terminal Block.
Specifications: Outputs; 16 outputs; NPN;
Without Short-circuit and,
Disconnected Line Detection.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring materiial cost can be reduced GRT1-DA2C.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on sitee GRT1-DA2C.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error.