LK Automation Limited LK Automation Limited
Brand: OMRON
Go Back >> Product Catalogues
G9SX-NS202-RT Compact Non-Contact Door Switch/Non-Contact Door Switch Controller
OMRON G9SX-NS202-RT Manual And Instructions
G9SX-NS202-RT datasheetPDF datasheet
G9SX-NS202-RT USER'S MANUAL

OMRON G9SX-NS202-RT Product information and technical parameters:
Brand: OMRON
Name: Compact Non-Contact Door Switch/Non-Contact Door Switch Controller
Model: G9SX-NS202-RT
Safety outputs *1: Instantaneous, 2 (Semi conductors); OFF-delayed*2, 0.
Auxiliary outputs *3: 2 (Semi conductors).
Logical AND connection input: 1.
Logical AND connection output: 1.
Max. OFF delay time *4: --.
Rated voltage: 24 VDC.
Terminal block type: Screw terminals.
Electronic Detection Mechanism for.
Better Stability in Non-contact Door.
Switch Operation.

Release Key Type: Standard (metal).
Wiring method: Terminal block.
Solenoid voltage/Indicator: 24VDC (Orange).
Lock and release type: Solenoid lock Mechanical release.
Contact configuration (door open/closed detection switch,
and lock monitor switch contacts): 6-contact Model,
Insert the built-in switch (N, P, Q or R) into the blank @ G9SX-NS202-RT.
Conduit size (See Note.): 1/2-14NPT.
World''s smallest Class 6-contact Guard Lock G9SX-NS202-RT
Safety-door Switch.
.
Wiring time is reduced with two types of wiring.
methods capable of one-touch attachment and removal.
A wide variety of built-in switches can be used for various devices.
(4-, 5-, and 6-contact models are available) G9SX-NS202-RT.
Key holding force of 1,300 N.
It is possible to change the key insertion point.
without detaching the head.
Drive solenoids directly from the Controller.
.
Lockout Key to prevent workers from becoming.
trapped inside the hazardous area.
The vertical D4SL Guard Lock Safety-door Switch,
can be easily mounted on 40 × 40 mm aluminum frames.
The plastic material makes the Slide Key suitable,
for lightweight doors G9SX-NS202-RT. Number of beams: 96.
Protective height: 1,950mm.
Model: PNP.
Easy-to-use Safety Sensor Ideal for.
Simple On/Off Detection Applications.
Provides simple safety functions - saving TCO.
by reducing errors.
Simple wiring with only 4 wires.
Fast response time of 5 ms. Holding Force of 3,000 N.
Two safety circuits and two monitor contacts provide an,
array of monitoring patterns.
Standard gold-clad contacts enable use with ordinary loads,
and microloads.
Models with trapped keys prevent workers from being locked,
in hazardous work areas.
Models with rear release buttons allow people to unlock the,
Switch and escape if they are locked into hazardous areas.
IP67 degree of protection. Name: Safety Controller.
Number of I/O: Safety inputs, 20; Test outputs, 6;
Safety outputs, Solid-state outputs: 8; Standard outputs, --.
Unit version: Ver.2.0.
Easy programming for complex safety control.
Stand-alone Safety Controller for small and mid-sized machinery.
Three types of CPU with different I/O size to suit the application.
Four types of Expansion I//O Units for hard-wired diagnosis or standard signals G9SX-NS202-RT.
Clear diagnosis and monitoring via Ethernet or Serial connection.
Various kinds of safety devices directly connectable like noncontact,
switches and safety mats.
Easy design, vverification, standardization and reusage of,
safety control by unique programming software G9SX-NS202-RT.
ISO 13849-1 (PLe/Category 4), IEC61508 (SIL3) certified.


...More relevant models >>>>