Terminal (wire connection): Screw terminal.
Applicable output load: DC load.
Zero cross function: --.
Rated input voltage: AC 200V.
slim I/O solid state relay.
control panel.
in comparison with conventional screw terminals.
traditional screw terminals.).
realizing high reliability.
screwdriver to achieve easier wiring work for stranded wires.
Screw terminal is also stocked to meet the screw type needs.
Mounted relay or solid-state relay has a plug-in terminal.
that is difficult to bend at the time of exchange.
Classification: Relay with Auxiliary Contact Block.
Structure: 4 poles + 2 poles.
Contact configuration: Relay, 3PST-NO/SPST-NC; Auxiliary Contact Block, DPST-NC.
Rated Voltage: 12, 24 VDC.
Compact Electromagnetic Contactors That.
Switch 40 A at 440 VAC.
One pole carries 40 A.
UL 508 and UL 840 NC contacts (resistive 40 A 480 VAC, 60 Hz, 80,000 operations) G3RV-SR700-D AC200.
EN 60947-4-1 NC contacts (AC1 40 A 440 VAC, 50/60 Hz, 80,000 operations)
G3RV-SR700-D AC200
Ideal for supply power to industrial inverters, servo drivers, and other devices,
and switching power to motors and other equipment.
The maximum load capacity of 160 A when using 4-pole parallel connections.
EN 60947-4-1 certification for mirror contact mechanism obtained by combining,
the Relay with an Auxiliary Contact Block G3RV-SR700-D AC200.
Conforms to European PV standard (VDE0126).
Approx. 30% less operation noise than a standard electromagnetic contactor.
(Approx. 100 dB reduced to approx. 70 dB.)
Approx. 50% the volume of a standard electromagnetic contactor,
to help downsize control panels.
According to OMRON investigation of IIEC-AC1 50 A specifications G3RV-SR700-D AC200. Compact, Slim-profile SSRs with Heat Sinks.
Solid State Contactors for Three-phase.
Heaters Reduced Installation Work.
with DIN Track Mounting.
RoHS compliant.
Surge pass protection improved surge dielectric strength,
for output currents. (OMRON testing).
Slim design with 3-phase output and built-in heat sinks.
DIN Track mounting types and screw mounting types are available.
All DIN Track mounting types mount to DIN Track.
(applicable DIN Track: TR35-15Fe (IEC 60715)).
Conforms to UL, CSA, and EN standards (TÜV certification). Isolation: Photocoupler.
Zero cross function: Yes.
Indicator: NO.
Rated output load: 3 A at 100 to 240 VAC *1 .
Rated input voltage: 4 to 24 VDC G3RV-SR700-D AC200.
New Models with International Standards.
Added to G3H Series (-VD in model number).
Same Profile as LY1 and LY2 Bi-power.
Relays.
Certified by UL, CSA, and VDE (models numbers with a suffixx of “-VD”) G3RV-SR700-D AC200.
Socket type, same size as LY Power Relays.
Operation indicator provided to confirm input,
(models numbers with “N” before the suffix).