Terminal (wire connection): Push-In Plus Terminal.
Applicable output load: AC load.
Zero cross function: Yes.
Rated input voltage: AC/DC 48V.
slim I/O solid state relay.
control panel.
in comparison with conventional screw terminals.
traditional screw terminals.).
realizing high reliability.
screwdriver to achieve easier wiring work for stranded wires.
Screw terminal is also stocked to meet the screw type needs.
Mounted relay or solid-state relay has a plug-in terminal.
that is difficult to bend at the time of exchange.
Input terminals: Compact slotted screw terminals (detachable).
Isolation method: Phototriaccoupler.
Zero cross function: Yes.
Operation indicator: Yes.
Alarm output: 2 outputs (Heater Burnout Detection,
SSR Short-circuit Failure Detection).
Applicable load (See note.): 2 to 25 A, 100 to 240 VAC G3RV-SR500-A AC/DC48.
A New-concept SSR with Built-in.
Current Transformer.
Heater Burnout and SSR Short
G3RV-SR500-A AC/DC48
circuit Failure Detection.
Built-in Current Transformer (CT) helps reduce wiring steps.
Detects the burnout of any one of a group of heaters.
Detects the burnout of 3-phase heaters.
Detects SSR short-circuit failures.
Error detection level can be easily set with a switch.
Mounts to a DIN track or with screws G3RV-SR500-A AC/DC48.
Three types of input terminals available: M3 terminals,
screwless clamp terminals (detachable), or compact slotted,
screw terminals (detachable).
Certified for CSA and EN (TÜV).
The G3PF-2@@B-@@@ Series is UL certified. Arc barrier equipped with high insulation strength (AC2000V)Mounting type: W-bracket(see note).
Contact form: 4PST-NO.
Quick-connect terminals.
A High-capacity, High-dielectric-strength,
Multi-pole Relay Used Like a Contactor G3RV-SR500-A AC/DC48.
Miniature hinge for maximum switching power for motor loads,
as well as resistive and inductive loads.
No contact chattering for momentary voltage drops up to 50%,
of rated voltage.
Withstanding more than 4 kV between contacts that are differ,
ent in polarity and between the coil and contacts.
Flame-resistant materials (UL94V-0-qualifying) used for all in,
sulation material.
Standard models approved by UL and CSA.
Structure: Relays with Plug-in Terminals.
Classification: Models with diode for coil surge,
absorption (DC coil specification only).
Number of poles: 4.
Power-switching Compact.
General-purpose Relays.
The standard models include models that are,
compliant with the UL, CSA, and SEV safety.
standards and with the Electrical Appliances and,
Material Safety Act.
Equipped with an arc barrier for arc interruption.
Withstand voltages up to 2,000 V.
New built-in diode and built-in CR circuit models have,
joined the series.
The lineup also inccludes models that are compliant,
with the LR and VDE safety standards G3RV-SR500-A AC/DC48.
Single-pole and double-pole models have AC4,
ratings and DC2 ratings (operating coil ratings:
100/110 VAC, 110/120 VAC, 200/220 VAC, 220/240 VAC,
and 1100/110 VDC) G3RV-SR500-A AC/DC48.
Three-pole and four-pole models have AC4 ratings,
and DC2 ratings (operating coil ratings: 100/110,
VAC, 200/220 VAC and 100/110 VDC).