LK Automation Limited LK Automation Limited
Brand: OMRON
Go Back >> Product Catalogues
G3PE-545B-2H DC12-24 Solid State Contactors for Heaters
OMRON G3PE-545B-2H DC12-24 Manual And Instructions
G3PE-545B-2H DC12-24 datasheetPDF datasheet

OMRON G3PE-545B-2H DC12-24 Product information and technical parameters:
Brand: OMRON
Name: Solid State Contactors for Heaters
Model: G3PE-545B-2H DC12-24
Number of phases: Three-phase.
Insulation method: Phototriac coupler.
Operation indicator: Yes (yellow).
Rated input voltage: 12 to 24 VDC.
Zero cross function: Yes.
Type: Externally attached heat sinks.
Applicable load: 45 A, 200 to 480 VAC.
Number of pole: 2.
Compact, Slim-profile SSRs with Heat Sinks.
Solid State Contactors for Three-phase.
Heaters Reduced Installation Work.
with DIN Track Mounting.
RoHS compliant.
Surge pass protection improved surge dielectric strength,
for output currents. (OMRON testing).
Slim design with 3-phase output and built-in heat sinks.
DIN Track mounting types and screw mounting types are available.
All DIN Track mounting types mount to DIN Track.
(applicable DIN Track: TR35-15Fe (IEC 60715)).
Conforms to UL, CSA, and EN standards (TÜV certification).

Isolation: Phototriac.
Zero cross function: No.
Indicator: No.
Rated output load: 20 A at 100 to 240 VAC.
Rated input voltage(See note 1, 2.): 5VDC, 12VDC, 24VDC.
Compact, Low-cost, SSR Switching 5 to 20 A.
Wide load voltage range: 75 to 264 VAC. Both 100-V and,
200-V loads can be handled with the same model G3PE-545B-2H DC12-24.
Dedicated, compact aluminum PCB and power elements used.
Built-in varistor effectively absorbs external surges G3PE-545B-2H DC12-24
Quick-connect #110 input terminals and #250 output,
connections. (#187 input terminals and #250 output,
connections are available.).
“-US” models certified by UL, CSA, and IEC/EN (TÜV). Standard certification: No.
Insulation mode: three end two-way photoelectric switch G3PE-545B-2H DC12-24.
Zero trigger function: No.
Action indicator: there.
Applicable load of output: AC100 3A ~ 240V.
Input rated voltage: DC24V.
With the LY1, LY2 large power relay with the same shape of the G3H series, the new international standard certification (-VD type).
Achieved UL, CSA, EN (VDE certification) standard certification. (type -VD)
Socket terminal type of same size with LY (1 pole, 2 pole type) G3PE-545B-2H DC12-24.
A model with an action indicator to check the status of the input. (type N)Mounting type: PCB mounting.
Contact form: 3PST-NO/SPST-NC.
PCB terminals.
A High-capacity, High-dielectric-strength,
Multi-pole Relay Used Like a Contactor.
Miniature hinge for maximum switching power for motor loads,
as well as resistive and inductive loads.
No contact chattering for momentary voltage drops up to 50%,
of rated voltage.
Withstanding more than 4 kV between contacts that are differ,
ent in polarity and between the coil and contacts.
Flame-resistant materials (UL94V-0-qualifying) used for all in,
sulation material.
Standard models approved by UL and CSA. Classification: Output (single contact), SPDT.
Rated voltage: 12 VDC, 24 VDC.
Slim-styled I/O Relay Saves Space in Panel G3PE-545B-2H DC12-24.
SPST-NO, SPST-NC, and SPDT contact forms available for,
output (SPST-NO only for input).
Ultra-slim housing measuring 29 (W) x 10 (D) x 32 (H) mm.
All Output Relays provide a lonng endurance (1,000,000,
operations at 5 A), while all Input Relays provide microswitching,
power (100 μA at 1 V) G3PE-545B-2H DC12-24.
Approved by UL and CSA standards.


...More relevant models >>>>