LK Automation Limited LK Automation Limited
Brand: OMRON
Go Back >> Product Catalogues
G3J-T217BL DC12-24 Soft-start/stop Solid State Contactors
OMRON G3J-T217BL DC12-24 Manual And Instructions
G3J-T217BL DC12-24 datasheetPDF datasheet
G3J-T217BL DC12-24 datasheetPDF datasheet
G3J-T217BL DC12-24 datasheetPDF datasheet

OMRON G3J-T217BL DC12-24 Product information and technical parameters:
Brand: OMRON
Name: Soft-start/stop Solid State Contactors
Model: G3J-T217BL DC12-24
Number of elements: 3.
Insulation method: Phototriac.
Rated supply voltage: 12 to 24 VDC.
Input method: No-voltage input (open and short circuit input).
Applicable motor: 3.7 kW (17.4 A), 200 to 220 VAC.
Soft-start/stop Function Starts and Stops.
Three-phase Motors Smoothly and.
Economically.
Function like an inverter by holding down the starting current.
Comply with UL, CSA, IEC (400-V models only), and JEM.
requirements.
Mount with screws or to DIN tracks.
Compact monoblock construction for the G3J-T217BL.
(W: 100 × H: 100 × D: 110 mm) with a heat sink.
Snubber circuit and varistor are built-in.
Operation indicator.

Insulation method: Photocoupler.
Operation indicator: Yes (yellow).
Zero cross function: No.
Applicable output load: 150 A, 180 to 480 VAC.
Rated input voltage: 5 to 24 VDC.
High-power, Load-control SSRs with.
High Current of 75 or 150 A and High.
Voltage of 240 or 480 VAC.
RoHS compliant.
Models also available with no zero cross G3J-T217BL DC12-24.
Replaceable power elements.
Conforms to cULus standards and EN standards (TÜV certification) G3J-T217BL DC12-24 Input terminals: Compact slotted screw terminals (detachable).
Isolation method: Phototriaccoupler.
Zero cross function: Yes.
Operation indicator: Yes.
Alarm output: 2 outputs (Heater Burnout Detection,
SSR Short-circuit Failure Detection).
Applicable load (See note G3J-T217BL DC12-24. ): 2 to 35 A, 100 to 240 VAC.
A New-concept SSR with Built-in.
Current Transformer.
Heater Burnout and SSR Short.
circuit Failure Detection.
Built-in Current Transformer (CT) helps reduce wiring steps.
Detects the burnout of any one of a group of heaters.
Detects the burnout of 3-phase heaters.
Detects SSR short-circuit failures.
Error detection level can be easily set with a switch G3J-T217BL DC12-24.
Mounts to a DIN track or with screws.
Three types of input terminals available: M3 terminals,
screwless clamp terminals (detachable), or compact slotted,
screw terminals (detachable).
Certified for CSA and EN (TÜV).
The G3PF-2@@B-@@@ Series is UL certified. New Models with AC Power Supply Input and,
Monitor Output Equivalent to Non-contact,
SPST-NO Join the G3J-T Series,
Limiting the starting current saves energy.
Certified for UL and CSA.
Mounts with screws or to DIN Track.
Compact design with heat sinks (3.7-kW models: 100 × 100 ×130 mm (W × H × D)).
Builtt-in snubber circuit and thyristor G3J-T217BL DC12-24.
Built-in operation indicator. Structure: single stable type.
Contact structure: 1a.
Structure: high flux protection.
Coil rated voltage: DC24V.
Voltage resistant 10kV 1 pole 3A open close ssmall relay G3J-T217BL DC12-24.
High power electromagnetic loop is used to achieve high sensitivity (200mW).
Small relays, but can ensure the impact resistance of 10kV.


...More relevant models >>>>