LK Automation Limited LK Automation Limited
Brand: OMRON
Go Back >> Product Catalogues
G3J-T205BL-C AC100-240 Solid State Contactor
OMRON G3J-T205BL-C AC100-240 Manual And Instructions
G3J-T205BL-C AC100-240 datasheetPDF datasheet
G3J-T205BL-C AC100-240 datasheetPDF datasheet

OMRON G3J-T205BL-C AC100-240 Product information and technical parameters:
Brand: OMRON
Name: Solid State Contactor
Model: G3J-T205BL-C AC100-240
Number of elements: 3.
Isolation method: Phototriac coupler.
Rated powersupply voltage: 100 to 240 VAC.
Input method: No-voltage input (open and short circuited input).
Applicable monitor capacity (AC3): 0.75 kW (4.8 A), 200 to 220 VAC.
Monitor output: AC switching output.
New Models with AC Power Supply Input and,
Monitor Output Equivalent to Non-contact,
SPST-NO Join the G3J-T Series,
Limiting the starting current saves energy.
Certified for UL and CSA.
Mounts with screws or to DIN Track.
Compact design with heat sinks (3.7-kW models: 100 × 100 ×130 mm (W × H × D)).
Built-in snubber circuit and thyristor.
Built-in operation indicator.

Structure: Relays with Plug-in Terminals.
Classification: Standard models Compliance with Electrical,
Appliances and Material Safety Act.
Number of poles: 2.
Power-switching Compact.
General-purpose Relays.
The standard models include models that are,
compliant with the UL, CSA, and SEV safety G3J-T205BL-C AC100-240.
standards and with the Electrical Appliances and,
Material Safety Act.
Equipped with an arc barrier for arc interruption G3J-T205BL-C AC100-240
Withstand voltages up to 2,000 V.
New built-in diode and built-in CR circuit models have,
joined the series.
The lineup also includes models that are compliant,
with the LR and VDE safety standards.
Single-pole and double-pole models have AC4,
ratings and DC2 ratings (operating coil ratings:
100/110 VAC, 110/120 VAC, 200/220 VAC, 220/240 VAC,
and 100/110 VDC) G3J-T205BL-C AC100-240.
Three-pole and four-pole models have AC4 ratings,
and DC2 ratings (operating coil ratings: 100/110,
VAC, 200/220 VAC and 100/110 VDC). Classification: Input (bifurcated contact), SPST-NO.
Rated voltage: 12 VDC, 24 VDC, 100/110 VAC, 200/220 VAC.
Slim-styled I/O Relay Saves Space in Panel.
SPST-NO, SPST-NC, and SPDT contact forms available for,
output (SPST-NO only for input) G3J-T205BL-C AC100-240.
Ultra-slim housing measuring 29 (W) x 10 (D) x 32 (H) mm.
All Output Relays provide a long endurance (1,000,000,
operations at 5 A), while all Input Relays provide microswitching,
power (100 μA at 1 V).
Approved by UL and CSA standards. Input terminals: Screwless clamp terminals (detachable).
Isolation method: Phototriaccoupler.
Zero cross function: Yes.
Operation indicator: Yes.
Alarm output: 2 outputs (Heater Burnout Detection,
SSR Short-circuit Failure Detection).
Applicable load (See note.): 2 to 25 A, 100 to 240 VAC.
A New-concept SSR with Built-in.
Current Transformer.
Heater Burnout and SSR Short.
circuit Failure Detection.
Built-in Current Transformer (CT) helps reduce wiring steps.
Detects the burnout of any one of a group of heaters.
Detects the burnout of 3-phase hheaters G3J-T205BL-C AC100-240.
Detects SSR short-circuit failures.
Error detection level can be easily set with a switch.
Mounts to a DIN track or with screws.
Three types of input terminals available: M3 terminals,
screwless clamp termiinals (detachable), or compact slotted,
screw terminals (detachable) G3J-T205BL-C AC100-240.
Certified for CSA and EN (TÜV).
The G3PF-2@@B-@@@ Series is UL certified.