Isolation: Phototriac coupler.
Zero cross function: NO.
Indicator: NO.
Rated output load: 3 A at 100 to 240 VAC *1 .
Rated input voltage: 5 VDC.
New Models with International Standards.
Added to G3H Series (-VD in model number).
Same Profile as LY1 and LY2 Bi-power.
Relays.
Certified by UL, CSA, and VDE (models numbers with a suffix of “-VD”).
Socket type, same size as LY Power Relays.
(models numbers with “N” before the suffix).
Ontology: socket terminal type.
Contact structure: 2c, 2a.
Small mechanical locking type relay with manual push button.
Small size and high 71mm * 42.5mm width x depth 48.5mm. Quality is only 175g.
Set, reset, rapid response through the pulse signal.
The contact is made of gold plating process, and the contact is highly reliable G3H-203SL-VD DC5.
Please use the company''s PTF14A (LY4 relay) socket
G3H-203SL-VD DC5 Number of poles: 4 poles.
Classification: Models with single contacts.
Rated voltage: Standard products, 100/110 or 200/220 VAC, 12, 24 or 100/110 VDC;
Made-to-order items, 12, 24, 110/120, or 220/240 VAC, 48 VDC.
New Latching Levers for Circuit Checking.
Added to Our Best-selling.
MY General-purpose Relays G3H-203SL-VD DC5.
Now lead-free to protect the environment.
VDE certification (Germany).
Different colors of coil tape for AC and,
DC models to more easily distinguish them.
MY(S) models with latching levers added for,
easier circuit checking. Standard certification: No.
Action indicator: there.
Applicable load of output: DC5 2A ~ 110V.
Input rated voltage: AC100/110V.
Insulation: photo coupler G3H-203SL-VD DC5.
Zero trigger function: No.
And the MY type of the same shape of the G3F series of new international standard certification (-VD type).
Achieved UL, CSA, EN (VDE certification) standard certification. (type -VD)
Socket terminal type of same size with MY (2 pole type).
A model with an action indicator to check the status of the input. Isolation: Photo-voltage coupler.
Zero cross function: No.
Indicator: Yes.
Rated output load: 0.5 A at 24 to 240 VAC, 0.5 A at 24 to 110 VDC.
Rated input voltage: 24 VDC.
100-A-max. Leakage Current, No Bleeder.
Resistor Required.
1 mA to 500 mA micro-load switching.
Switch to both AC and DC with no polarity.
Switch for a wide range of voltages; 19 G3H-203SL-VD DC5. 2 to 264 VAC, 19.2 to 125 VDC.
Switch full- and half-wave rectifier AC loads.
Same sizes and terminal arrangements as OMRON Power,
Relay MY Series.
Operating indicator provided.
Switch MY Series (without bleeder resistor) G3H-203SL-VD DC5.
Superior surge absorption with a built-in varistor.
Optimum SSR to control minute load, valves, and solenoids.