Previously light curtains only offered status indicators.
status indicators but enable.
further enhancing usability.
Distributed Safety Terminals That.
Reduce Wiring.
Lineup includes four models to accommodate various,
I/O types and number of I/O points.
Monitor the safety system from Standard Controllers,
across the network.
EN954-1 (Cat.4), ISO13849-1 (PLe),
and IEC 61508 SIL3 certification.
The DST1-XD0808SL-1 also supports logic operation,
functions for high-speed processing in applications,
requiring partial stopping of the safety system F3SR-B Series
F3SR-B Series Actuator: Fork lever lock (left operation)V.
Conduit size: 1-conduit; G1/2.
Built-in switch mechanism: 2NC/2NO (Slow-action).
Popular Safety Limit Switches.
Providing a Full Lineup Conforming to,
International Standards.
Lineup includes models with 1NC/1NO, 2NC, 2NC/1NO and,
3NC contact forms F3SR-B Series.
(Slow-action models with MBB contacts are available.)
M12-connector models are also available, saving on labor and,
simplifying replacement.
Standardized gold-clad contacts provide high contact reliability.
Can be used with both standard loads and microloads.
Conforms to EN115-1, EN81-1, and EN81-2 (slow-action models only).
Certified standards: UL, EN (TÜV), and CCC F3SR-B Series. Actuator: One-way roller arm lever (vertical).
Conduit size: 1-conduit; M20.
Built-in switch mechanism: 1NC/1NO(Snap-action).
Popular Safety Limit Switches.
Providing a Full Lineup Conforming to,
International Standards.
Lineup includes models with 1NC/1NO, 2NC, 2NC/1NO and,
3NC contact forms.
(Slow-action models with MBB contacts are available.)
M12-connector models are also available, saving on labor and,
simplifying replacement.
Standardized gold-clad contacts provide high contact reliability.
Can be used with both standard loads and microloads.
Conforms to EN115-1, EN81-1, and EN81-2 (slow-action models only).
Certified standards: UL, EN (TÜV), and CCC. Number of beams: 66.
Protective height: 1320mm.
Safety Light Curtains with Durable,
Impact-resistant Body and Long,
20-m Sensing Distance.
MS/MSF4800A Advanced Series.
Programming and Diagnostics Module (PDM) makes it easy,
to set functionss F3SR-B Series.
Series connection is possible only with the MSF4800A.
Blanking can be set.
Muting is possible only with the MSF4800A by using the,
MS4800-RM6 Resource Module.
MS/MSF4800B Basic Series,
Features all necessary basic Safety Lightt Curtain functions F3SR-B Series.
Series connection is possible only with the MSF4800B.
Programming and Diagnostics Module (PDM) makes it easy,
to set functions.