LK Automation Limited LK Automation Limited
Brand: OMRON
Go Back >> Product Catalogues
F3SJ-B0305N25 Safety Light Curtain
OMRON F3SJ-B0305N25 Manual And Instructions
F3SJ-B0305N25 datasheetPDF datasheet
F3SJ-B0305N25 INSTRUCTION MANUAL
F3SJ-B0305N25 INSTRUCTION sheet

OMRON F3SJ-B0305N25 Product information and technical parameters:
Brand: OMRON
Name: Safety Light Curtain
Model: F3SJ-B0305N25
Number of beams: 14.
Protective height: 305mm.
Model: NPN output.
Basic Type with a combination of.
performance and functionality.
Up to three sets of series-connected sensors.
The muting function is enabled simply with Muting Key Cap.
Comes standard with interlock and auxiliary output functions.

Actuator: One-way roller arm lever (vertical).
Conduit size: 2-conduit; G1/2.
Built-in switch mechanism: 2NC (Slow-action).
A Series of Pull-reset Models Now.
Available.
Lineup includes three contact models with 2NC/1NO and 3NC,
contact forms in addition to the previous contact forms 1NC/1NO and 2NC F3SJ-B0305N25.
M12-connector models are available, saving on labor and,
simplifying replacement F3SJ-B0305N25
Standardized gold-clad contacts provide high contact reliability.
Can be used with both standard loads and microloads.
Conforms to EN115, EN81-1 and EN81-2.
Certified standards: UL, EN (TÜV), and CCC. Actuator: Adjustable rod lever.
Conduit openings: G1/2 (PF1/2).
1NC/1NO (Snap-action).
Robust safety limit switch with metal housing F3SJ-B0305N25.
Slow-action and snap-action contact with,
certified direct opening operation certification.
Direct opening mechanism (NC contacts only) added to,
enable opening contacts when faults occur, such as fused contacts.
Safety of lever settings ensured using a mechanism that,
engages a gear between the operating position indicator plate and the lever.
Equipped with a mechanism that indicates the applicable,
operating zone, as well as push-button switching to control left and right motion F3SJ-B0305N25.
Head seal structure strengthened to improve seal properties.
(TÜV: IEC IP67, UL: NEMA 3, 4, 4X, 6P, and 13).
Wide standard operating temperature range: –40 to 80°C (standard type).
Certified standards: UL, CSA, EN (TÜV), and CCC.
Name: Safety I/O Terminals.
No. of I/O points: Safety inputs: 8, safety outputs (semiconductor): 8,
test outputs: 4.
Distributed Safety Terminals That.
Reduce Wiring.
Lineupp includes four models to accommodate various,
I/O types and number of I/O points F3SJ-B0305N25.
Monitor the safety system from Standard Controllers,
across the network.
EN954-1 (Cat.4), ISO13849-1 (PLe),
and IEC 61508 SIL3 certification.
The DST1-XD0808SL-1 also supports logic operation,
functions for high-speed processing in applications,
requiring partial stopping of the safety system F3SJ-B0305N25.