Number of beams: 199.
Protective height: 2000mm.
Model: NPN output.
Easy-to-use Safety Sensor Ideal for.
Simple On/Off Detection Applications.
Provides simple safety functions - saving TCO.
by reducing errors.
Simple wiring with only 4 wires.
Fast response time of 5 ms.
Actuator: One-way roller arm lever (vertical).
Conduit size: 1-conduit; G1/2.
Built-in switch mechanism: 1NC/1NO (Slow-action).
A Series of Pull-reset Models Now.
Available.
Lineup includes three contact models with 2NC/1NO and 3NC,
contact forms in addition to the previous contact forms 1NC/1NO and 2NC F3SG-4RE2000N14.
M12-connector models are available, saving on labor and,
simplifying replacement
F3SG-4RE2000N14
Standardized gold-clad contacts provide high contact reliability.
Can be used with both standard loads and microloads.
Conforms to EN115, EN81-1 and EN81-2.
Certified standards: UL, EN (TÜV), and CCC. Number of beams: 14.
Protective height: 305mm.
Model: PNP output.
EASY type reduces implementation costs F3SG-4RE2000N14.
with 1/2 the mounting time.
In pursuit of simple functions: Upon detection of personnel,
the machine stops.
Can be used for simple hand intrusion detection.
Implementation costs can be significantly reduced. Actuator: One-way roller arm lever (vertical).
Conduit size: 1-conduit; M20.
Built-in switch mechanism: 2NC (Slow-action).
Popular Safety Limit Switches.
Providing a Full Lineup Conforming to,
International Standards F3SG-4RE2000N14.
Lineup includes models with 1NC/1NO, 2NC, 2NC/1NO and,
3NC contact forms.
(Slow-action models with MBB contacts are available.)
M12-connector models are also available, saving on labor and,
simplifying replacement.
Standardized gold-clad contacts provide high contact reliability.
Can be used with both standard loads and microloads.
Conforms to EN115-1, EN81-1, and EN81-2 (slow-action models only).
Certified standards: UL, EN (TÜV), and CCC. Name: Safety Network Controllers.
No. of I/O points: Safety inputs, 12 *; Test outputs, 2; Safety outputs, 6.
Unit version: Ver. 1.0.
Safety inputs Test outputs Safety outputs
New Lineup for Safety Applications,
with Up to 12 Inputs.
Circuits for the required safety category are easy to buildd F3SG-4RE2000N14.
The safety circuits you create can be registered as templates,
and reused, for easy standardization.
A wide range of TÜV-certified templates is also available.
The NE0A operating conditions can be monitored from a,
standard DeviceNet Master F3SG-4RE2000N14.
Network distribution is possible by combining with an NE1A,
Safety Controller.
ISO13849-1 (PLe) and IEC 61508 SIL3 certification.