Type: medium temperature.
Measuring temperature range: 0 ~ +500.
The target size: 3mm diameter (from 30mm).
No need to contact the workpiece, you can measure the temperature.
Achieve no damage, health and efficient temperature management.
A small spot diameter 3mm and 8mm diameter two types.
Reproduction of positive and negative 0.5 degrees Celsius, response speed of 0.4 seconds,
(95%) with high precision and high speed measurement.
High temperature (0 ~ +1000 degrees C) models.
New measurement distance up to 500mm, 1000mm long distance type.
Moving average function and output range.
Size: 48 x 96mm.
Control output 1: linear current output.
Control output 2:--.
Auxiliary output: 4 points (auxiliary output 2, 1 common, auxiliary output 3, 4 public general).
Power supply voltage: AC/DC24V.
Terminal shape: screw terminal table type.
Input category: full range multi input.
Heating wire break, SSR fault detection function: - ES1-LP3.
Communication: -.
Event input: 4 points
ES1-LP3
Remote SP input: -.
Transfer output: -.
Large screen display white PV legible. From selection to setting and operation are simple and easy to use.
Full capacity, function and performance of I/O. Suitable for more applications.
E5AC white LCDPV display height is about 25mm.
The upper panel and the front panel are equipped with tool ports ES1-LP3.
With the communication conversion line (sold separately) connected to the computer to establish the controller without the need to install the wire for power supply.
Easy to install CX-Thermo (sold separately).
50ms high speed sampling period.
Model can be equipped with up to 4 point auxiliary output, 6 point event input,
1 point transfer output and remote SP input, suitable for a wide range of applications ES1-LP3.
The main body is short, the thickness is only 60mm.
Easy to use programmable logic controller (PLC) is connected to the programmable logic controller (PLC).
The temperature controller is connected to each other by using the component communication.
A new type of proportional control allows you to control the valve. Size: 48 x 96mm.
Ontology: terminal type, temperature input type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output: relay output.
Control mode: standard or heating cooling.
Auxiliary output points: 1 points.
A power supply for the detection of /ES1B fault, SSR fault and heater over current for heater use.
Event input points: -.
Transfer output: -.
Communication: -.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of /.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance.
Add PV/SV state display function, to see the state of the thermostat
(aautomatic / manual, RUN/STOP, alarm), interactive display PV/SV ES1-LP3.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Increased the 3 segment display, which cann display the current value / target / operation ES1-LP3.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc., can be a key operation.