LK Automation Limited LK Automation Limited
Brand: OMRON
Go Back >> Product Catalogues
E5EN-Q3H01TD-FLK-N Foundation type temperature controller
OMRON E5EN-Q3H01TD-FLK-N Manual And Instructions
E5EN-Q3H01TD-FLK-N datasheetPDF datasheet
E5EN-Q3H01TD-FLK-N datasheetPDF datasheet
E5EN-Q3H01TD-FLK-N datasheetPDF datasheet
E5EN-Q3H01TD-FLK-N Basic TypeUser's Manual
E5EN-Q3H01TD-FLK-N User's Manual
E5EN-Q3H01TD-FLK-N User's Manual
E5EN-Q3H01TD-FLK-N User's Manual
E5EN-Q3H01TD-FLK-N Communications FunctionsUser's Manual
E5EN-Q3H01TD-FLK-N INSTRUCTION Manual
E5EN-Q3H01TD-FLK-N INSTRUCTION Manual

OMRON E5EN-Q3H01TD-FLK-N Product information and technical parameters:
Brand: OMRON
Name: Foundation type temperature controller
Model: E5EN-Q3H01TD-FLK-N
Size: 48 x 96mm.
Ontology: terminal type, temperature input type.
Type: control output 1 point type (power AC/DC24V).
Shell color: black.
Control output: voltage output (SSR driver).
Control mode: standard or heating cooling.
Auxiliary output points: 3 points.
Heater with broken wire, SSR fault, heater over current detection function /ES1B power supply: single phase heater with detection function.
Event entry point: 2.
Transfer output: -.
Communication: -.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of /.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Increased the 3 segment display, which can display the current value / target / operation.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc., can be a key operation.

Classification: General purpose Models.
Description: Standard thermocouple.
Temperature range (See note 3.): 0°C to 1,400°C.
Element type: R (PR).
Conductor type: Non grounded type.
Class: 2 (0.25).
Protective tubing material: JIS ceramic JIS special ceramic.
Terminal type: Enclosed terminals E5EN-Q3H01TD-FLK-N.
Page: 16.
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work E5EN-Q3H01TD-FLK-N
Ideal for the thermal input devices of Temperature Controllers.
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal E5EN-Q3H01TD-FLK-N. Terminal type: Exposed-lead Models.
Protective tubing diameter D: 4.8 dia.
Protective tubing length L: 50cm.
Lead wire type: Standard.
Lead wire length M: 4m.
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work.
Ideal for the thermal input devices of Temperature Controllers E5EN-Q3H01TD-FLK-N.
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal. Size: 1/16 DIN.
Case color: Black.
Power supply voltage: 100 to 240 VAC.
Input type: Thermocouple or Resistance thermometer.
Auxiliary outputs: 2.
Control output 1: Current output.
New 48 x 48-mm Basic Temperature.
Controller with Enhanced Functions and,
Performance. Improved Indication Accuracy,
and Preventive Maintenance Function.
Indication Accuracy.
Thermocouple input: ±0.3% of PV (previous models: ±0.5%),
Pt input: ±0.2% of PV (previous models: ±0.5%),
Analog input: ±0.2% FS (previous models: ±0 E5EN-Q3H01TD-FLK-N. 5%),
New E5CN-U Models (Plug-in Models) with analog inputs and,
current outputs.
A PV/SV-status display function can be set to automatically alternate,
between displaying the status of the Temperature Controller (auto/
mannual, RUN/STOP, and alarms) and the PV or SV E5EN-Q3H01TD-FLK-N.
Preventive maintenance for relays in the Temperature,
Controller using a Control Output ON/OFF Counter.


...More relevant models >>>>