The use of communication adapter cable (sold separately) connected to the computer after,
With auxiliary output (4 points), event input (maximum 6 points), the transmission output,
Add position proportional control type, also support control valve control.
Terminal type: Exposed-lead Models.
Protective tubing diameter D(mm): 3.2 dia.
Protective tubing length L: 20 cm.
Lead wire type: Standard.
Lead wire length M: 8m.
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work E5EC-TCX4ASM-064.
Ideal for the thermal input devices of Temperature Controllers
E5EC-TCX4ASM-064
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal. Size: 48 x 48mm.
Control output 1: voltage output (SSR driver).
Control output 2:--.
Auxiliary output: 2 independent points E5EC-TCX4ASM-064.
Power supply voltage: AC/DC24V.
Terminal type: screw terminal table type.
Input category: full range multi input.
Heater break, SSR fault detection function: -.
Communication: -.
Event input: 2 points.
Remote SP input: -.
Transfer output: have.
Using large font PV display (white), improve visibility.
Selection, operation and setting.
Functional performance of input and output points E5EC-TCX4ASM-064.
Support for more extensive range of applications.
Using high PV 15.2mm display (white), improve visibility.
High speed sampling to achieve 50ms.
With auxiliary output (maximum 3 points), event input (maximum 4 points), the transmission output,
Remote SP input function, support for a variety of applications.
E5CC 60mm has a depth of slender body.
The use of communication adapter cable (sold separately) connected with a computer.
After that, no power supply connection can be set.
It can be easily set by CX-Thermo (sold separately).
Easy to connect with PLC through no program communication.
Combined temperature control device through component communication. Control output 1: Linear current output.
Auxiliary output: Two.
Communications: RS-485.
Heater burnout: --.
Event inputs: Two.
Power supply voltage: 24 VAC/VDC.
Large White PV Display That’s Easier to Read.
Easy to Use, from Model Selection to,
Setup andd Operation E5EC-TCX4ASM-064.
A Complete Range of I/O Capacities,
Functions, and Performance.
Handles More Applications.
The white PV display with a height of 15.2 mm improves visibility.
High-speed sampling at 50 ms.
Short body with depth of only 60 mm E5EC-TCX4ASM-064.
Easy connections to a PLC with programless communications.
Use component communications to link Temperature.
Controllers to each other.