LK Automation Limited LK Automation Limited
Brand: OMRON
Go Back >> Product Catalogues
E5CN-Y2L Foundation type temperature controller
OMRON E5CN-Y2L Manual And Instructions
E5CN-Y2L datasheetPDF datasheet
E5CN-Y2L datasheetPDF datasheet
E5CN-Y2L Basic TypeBasic Type
E5CN-Y2L User's Manual
E5CN-Y2L User's Manual
E5CN-Y2L Communications FunctionsUser's Manual
E5CN-Y2L USER'S MANUAL
E5CN-Y2L Communications FunctionsUser's Manual
E5CN-Y2L USER'S MANUAL

OMRON E5CN-Y2L Product information and technical parameters:
Brand: OMRON
Name: Foundation type temperature controller
Model: E5CN-Y2L
Ontology: terminal type, analog input type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output: relay output and long life.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
A power supply for the detection of /ES1B fault, SSR fault and heater over current for heater use.
Event input points: -.
Transfer output: -.
Communication: -.
48mm general thermostat has been upgraded & function / performance upgrade.
Indicates that the accuracy is increased and the preventive maintenance function is increased,
Further performance improvement.
E5CN-U (insert type) add analog input and current output type.
Add PV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactive display PV/SV.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.

Type: temperature measurement impedance type.
Adjustment mode: ON/OFF action or PID action.
Alarm: there.
Output: relay output.
Digital universal single display electronic temperature controller DIN 48 * 48mm self tuning (self-tuning) PID control. "Size: 48 * 48mm, terminal type.
Type: control output 1 point type (power AC/DC24V) E5CN-Y2L.
Shell color: black.
Control output: relay output.
Control mode: standard or heating cooling E5CN-Y2L
Auxiliary output points: 2 points.
Heater break, SSR fault detection function: single phase heater detection function.
Event entry point: 2.
Transfer output: -.
Communication: RS-485.
New program type.
A new type of liquid crystal with high performance cost ratio is adopted in the 256 paragraph,
Visual angle, contrast can be improved E5CN-Y2L.
Can be set up to 8 procedures (mode) x 32 (step) procedure.
High resolution 5 bit display / can display 0.01 degrees C (to achieve a small size of 48 x 48mm).
High speed sampling period 60ms.
Full of all models (capable of thermocouple /Pt/ analog input switching),
1 machines to support a variety of sensors.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/RESET, alarm),
Interactive display PV/SV E5CN-Y2L.
By supporting software (Ver.4.3 CX-Thermo),
In simple arithmetic functions (AND/OR logic and delay).
Setting the program settings that can perform flexible contact output.
The control output ON/OFF times counting function can predict the fault of the internal relay of the temperature controller. Terminal type: Exposed-lead Models.
Protective tubing diameter D(mm): 4.8 dia.
Protective tubing length L: 35 cm.
Lead wire type: Standard.
Lead wire length M: 8m.
A Wide Variety of High-precision. E5CN-Y2L.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work.
Ideal for the thermal input devices of Temperature Controllers.
Select from a wide variety of Teemperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal E5CN-Y2L.


...More relevant models >>>>