LK Automation Limited LK Automation Limited
Brand: OMRON
Go Back >> Product Catalogues
E5CN-HTR2HH03D-FLK Programmed temperature controller
OMRON E5CN-HTR2HH03D-FLK Manual And Instructions
E5CN-HTR2HH03D-FLK datasheetPDF datasheet
E5CN-HTR2HH03D-FLK Programmable TypeBasic Type
E5CN-HTR2HH03D-FLK Programmable TypeUser's Manual
E5CN-HTR2HH03D-FLK User's Manual
E5CN-HTR2HH03D-FLK Basic TypeBasic Type
E5CN-HTR2HH03D-FLK User's Manual
E5CN-HTR2HH03D-FLK User's Manual
E5CN-HTR2HH03D-FLK Communications FunctionsUser's Manual
E5CN-HTR2HH03D-FLK USER'S MANUAL
E5CN-HTR2HH03D-FLK Communications FunctionsUser's Manual
E5CN-HTR2HH03D-FLK USER'S MANUAL
E5CN-HTR2HH03D-FLK INSTRUCTION Manual

OMRON E5CN-HTR2HH03D-FLK Product information and technical parameters:
Brand: OMRON
Name: Programmed temperature controller
Model: E5CN-HTR2HH03D-FLK
Size: 48 * 48mm, terminal type.
Type: control output 1 point type (power AC/DC24V).
Shell color: black.
Control output: relay output.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater break, SSR fault detection function: single phase or three phase heater detection function.
Event entry point: 2.
Transfer output: -.
Communication: RS-485.
New program type.
A new type of liquid crystal with high performance cost ratio is adopted in the 256 paragraph,
Visual angle, contrast can be improved.
Can be set up to 8 procedures (mode) x 32 (step) procedure.
High resolution 5 bit display / can display 0.01 degrees C (to achieve a small size of 48 x 48mm).
High speed sampling period 60ms.
Full of all models (capable of thermocouple /Pt/ analog input switching),
1 machines to support a variety of sensors.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/RESET, alarm),
Interactive display PV/SV.
By supporting software (Ver.4.3 CX-Thermo),
In simple arithmetic functions (AND/OR logic and delay).
Setting the program settings that can perform flexible contact output.
The control output ON/OFF times counting function can predict the fault of the internal relay of the temperature controller.

Classification: General purpose Models.
Description: Sheathed thermocouple.
Temperature range (See note 3.): 0°C to 900°C.
Element type: K (CA) J (IC).
Conductor type: Non grounded type.
Class: 2 (0.75).
Protective tubing material: ASTM316L.
Terminal type: Exposed terminals.
Page: 13.
A Wide Variety of High-precision E5CN-HTR2HH03D-FLK.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work E5CN-HTR2HH03D-FLK
Ideal for the thermal input devices of Temperature Controllers.
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal E5CN-HTR2HH03D-FLK. Protective tubing length L: 20cm.
Protective tubing diameter: D = 6.4.
L2: 150 mm.
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work.
Ideal for the thermal input devices of Temperature Controllers.
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal E5CN-HTR2HH03D-FLK. Case color: Black.
Control output: Relay output.
Control mode *1: Standard or heating/cooling.
No. of auxiliary outputs: 1.
Detection of heater burnout, SSR failure, and heater overcurrent: --.
No. of event inputs: --.
Transfer output *2: --.
Communi cations: --.
Previous model: Thermocouple input, E5GN-R1TC;
Resistance thermometer input, E5GN-R1P.
New 48 x 24-mm Basic Temperature,
Controller with Enhanced Functions and,
Performance. Improved Indication Accuracy,
and Preventive Maintenance Function.
Indication Accuracy.
Thermocouple input: ±0.3% of PV (previous models: ±0.5%),
Pt input: ±0.2% of PV (previous models: ±0.5%),
Analog input: ±0.2% FS (previous models: ±0.5%),
Models are available with screw terminal blocks or screwless,
clamp terminal blocks.
A PV/SV-status display function can be set to automatically alternate,
between displaying the status of thhe Temperature Controller (auto/
manual, RUN/STOP, and alarms) and the PV or SV E5CN-HTR2HH03D-FLK.
Preventive maintenance for relays in the Temperature,
Controller using a Control Output ON/OFF Counter.
Switch the PV display between three colorrs E5CN-HTR2HH03D-FLK.
Compatible with Support Software (CX-Thermo version 4.2 or higher).
Eleven-segment displays.
Models are available with one or two alarm outputs.


...More relevant models >>>>