OMRON E5CN-HTQ2H03-FLK Product information and technical parameters:
Brand: OMRON
Name: Programmed temperature controller
Model: E5CN-HTQ2H03-FLK
Size: 48 * 48mm, terminal type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output: voltage output (SSR driver).
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater break, SSR fault detection function: single phase heater detection function.
Event entry point: 2.
Transfer output: -.
Communication: RS-485.
New program type.
A new type of liquid crystal with high performance cost ratio is adopted in the 256 paragraph,
Visual angle, contrast can be improved.
Can be set up to 8 procedures (mode) x 32 (step) procedure.
High resolution 5 bit display / can display 0.01 degrees C (to achieve a small size of 48 x 48mm).
High speed sampling period 60ms.
Full of all models (capable of thermocouple /Pt/ analog input switching),
1 machines to support a variety of sensors.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/RESET, alarm),
Interactive display PV/SV.
By supporting software (Ver.4.3 CX-Thermo),
In simple arithmetic functions (AND/OR logic and delay).
Setting the program settings that can perform flexible contact output.
The control output ON/OFF times counting function can predict the fault of the internal relay of the temperature controller.

Size: 96 × 96 mm.
Control type: Basic control (1 loop).
Control mode: Standard control Heating and cooling control.
Outputs(control/transfer): 2 (pulse + pulse/current).
Optional functions: Auxiliary outputs (SUB), 4; Event inputs, 2;
Serial communications, None.
A new High-speed, High-precision Digital E5CN-HTQ2H03-FLK.
Controller that is Programmable!
Create up to 32 programs with up to 256 segments total E5CN-HTQ2H03-FLK
Coordinated operation for up to four channels with one Digital Controller.
0.01°C High resolution for Pt input.
High-speed sampling at 50 ms.
Settings easily made from a computer using the CX-Thermo.
RoHS compliance for world-wide application. Size: 48 x 24mm.
Control output 1: linear current output E5CN-HTQ2H03-FLK.
Control output 2:--.
Auxiliary output: 2 points.
Power supply voltage: AC/DC24V.
Terminal type: PUSH-IN fastening terminal table type.
Input category: full range multi input.
Heater break, SSR fault detection function: -.
Communication: -.
Event input: -.
A small body of 48 * 24mm specifications on the condensation operation, E5_C series of high performance.
Slender body width 48mm * 24mm * 90mm high depth,
The most suitable for small devices / physical and chemical equipment, etc E5CN-HTQ2H03-FLK. .
Although the small size, but also through the character of the high 10.5mm white PV display to achieve high recognition.
The terminal stage is adopted to disassemble and assemble the structure, which improves the maintenance performance.
The connection method can be selected from a screw terminal and a PUSH-IN fastening terminal.
High speed sampling of 50ms is realized.
Easy to connect with PLC through no program communication.
The use of electric communication conversion Village (sold separately) connected to the computer after,
No power connection can be set.
It can be easily set by CS-Thermo (sold separately). Size: 96 x 96mm.
Control output 1: voltage.
Auxiliary (alarm) output: 4.
Transfer output: have.
Event input: 4.
Communication: RS-485.
Disconnection detection: 2.
Power supply voltage: AC100 ~ 240V.
E5 - C series of new products program.
Maximum 256 segment of the program capacity,
Support for multiple applications.
Can be set up to 8 procedures (mode) x 32 (step) procedure.
The use of high 25mm (E5AC-T), 18mm (E5AC-T) PV display (white),
Improve visibility.
Not only on the top of the body, but also on the front,
The use of communication adapter cable (sold separately) connected to the computer after,
No power connection can be set.
It can be easily set by CX-Thermo (sold separately).
High speed sampling to achieve 50ms E5CN-HTQ2H03-FLK.
With auxiliary output (4 points), event input (maximum 6 points), the transmission output,
Support a variety of applications.
Slender fuselage depth 60mm.
Easy to connect with PLC through no program communicatiion E5CN-HTQ2H03-FLK.
Combined temperature control device through component communication.
Add position proportional control type, also support control valve control.