LK Automation Limited LK Automation Limited
Brand: OMRON
Go Back >> Product Catalogues
E5CN-CQ2BL Foundation type temperature controller
OMRON E5CN-CQ2BL Manual And Instructions
E5CN-CQ2BL datasheetPDF datasheet
E5CN-CQ2BL datasheetPDF datasheet
E5CN-CQ2BL Basic TypeUser's Manual
E5CN-CQ2BL User's Manual
E5CN-CQ2BL User's Manual
E5CN-CQ2BL Communications FunctionsUser's Manual
E5CN-CQ2BL USER'S MANUAL
E5CN-CQ2BL Communications FunctionsUser's Manual
E5CN-CQ2BL USER'S MANUAL

OMRON E5CN-CQ2BL Product information and technical parameters:
Brand: OMRON
Name: Foundation type temperature controller
Model: E5CN-CQ2BL
Ontology: terminal type, analog input type.
Category: control output 2 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output 1: current output.
Control output 2: voltage output (SSR driver).
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
A power supply for the detection of /ES1B fault, SSR fault and heater over current for heater use.
Event entry point: 2.
Transfer output: output (using control output).
Communication: -.
48mm general thermostat has been upgraded & function / performance upgrade.
Indicates that the accuracy is increased and the preventive maintenance function is increased,
Further performance improvement.
E5CN-U (insert type) add analog input and current output type.
Add PV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactive display PV/SV.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.

Classification: Low-cost Models.
Description: Low-cost platinum resistance thermometer.
Temperature range (See note 3.): -50°C to 250°C.
Element type: Pt100.
Conductor type: 3-conductor system.
Class: B.
Protective tubing material: SUS304.
Terminal type: Exposed lead wires.
Page: 37.
A Wide Variety of High-precision E5CN-CQ2BL.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work E5CN-CQ2BL
Ideal for the thermal input devices of Temperature Controllers.
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal E5CN-CQ2BL. Terminal type: Exposed-lead Models.
Protective tubing diameter D (mm): 1.6 dia.
Protective tubing length L: 35cm.
Lead wire type: Standard.
Lead wire length M : 4m.
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work.
Ideal for the thermal input devices of Temperature Controllers E5CN-CQ2BL.
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal. Size: 48 x 96mm.
Ontology: terminal type, temperature input type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output: relay output.
Control mode: standard or heating cooling.
Auxiliary output points: 3 points.
Heater with broken wire, SSR fault, heater over current detection function /ES1B power supply: ES1B power supply.
Event entry point: 2.
Transfer output: -.
Communication: -.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of /.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance.
Add PV/SV state display function, to see the state of the thermostat
(autoomatic / manual, RUN/STOP, alarm), interactive display PV/SV E5CN-CQ2BL.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Increased the 3 segment display, which cann display the current value / target / operation E5CN-CQ2BL.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc., can be a key operation.