LK Automation Limited LK Automation Limited
Brand: OMRON
Go Back >> Product Catalogues
E5AN-HTAA2HH03BD-FLK Programmed temperature controller
OMRON E5AN-HTAA2HH03BD-FLK Manual And Instructions
E5AN-HTAA2HH03BD-FLK datasheetPDF datasheet
E5AN-HTAA2HH03BD-FLK Programmable TypeBasic Type
E5AN-HTAA2HH03BD-FLK Programmable TypeUser's Manual
E5AN-HTAA2HH03BD-FLK User's Manual
E5AN-HTAA2HH03BD-FLK Basic TypeUser's Manual
E5AN-HTAA2HH03BD-FLK User's Manual
E5AN-HTAA2HH03BD-FLK User's Manual
E5AN-HTAA2HH03BD-FLK Communications FunctionsUser's Manual
E5AN-HTAA2HH03BD-FLK INSTRUCTION Manual
E5AN-HTAA2HH03BD-FLK INSTRUCTION Manual

OMRON E5AN-HTAA2HH03BD-FLK Product information and technical parameters:
Brand: OMRON
Name: Programmed temperature controller
Model: E5AN-HTAA2HH03BD-FLK
Size: 96 x 96mm.
Type: power AC/DC24V with.
Shell color: black.
Control output 1: output unit mode.
Control output 2: output unit mode.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater break, SSR fault detection function: single phase or three phase heater detection function.
Event entry point: 2.
Transfer output: -.
Remote SP:4 to 20mA input.
Communication: RS-485.
New program type.
A new type of liquid crystal with high performance cost ratio is adopted in the 256 paragraph,
Visual angle, contrast can be improved.
Can be set up to 8 procedures (mode) x 32 (step) procedure.
High resolution 5 bit display / can display 0.01 degrees C.
High speed sampling period 60ms.
All models complete a variety of (to the thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors.
Also supports remote SP.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/RESET, alarm), interactive display PV/SV.
Through the support software (Ver.4.3 CX-Thermo) makes the process of setting management becomes very
Simple use of simple computing functions (AND/OR logic and delay) to set the implementation of flexible contact output.
Through the infrared port can be carried out from the front of the communication.
The control output ON/OFF times counting function can predict the fault of the internal relay of the temperature controller.

Size: 48 x 24mm.
Control output 1: relay output.
Control output 2:--.
Auxiliary output: 2 points.
Power supply voltage: AC100 ~ 240V.
Terminal type: screw terminal table type (with terminal cover).
Input category: full range multi input.
Heater disconnection, SSR fault detection function: 1 points E5AN-HTAA2HH03BD-FLK.
Communication: -.
Event input: -.
A small body of 48 * 24mm specifications on the condensation operation, E5_C series of high performance E5AN-HTAA2HH03BD-FLK
Slender body width 48mm * 24mm * 90mm high depth,
The most suitable for small devices / physical and chemical equipment, etc..
Although the small size, but also through the character of the high 10.5mm white PV display to achieve high recognition E5AN-HTAA2HH03BD-FLK.
The terminal stage is adopted to disassemble and assemble the structure, which improves the maintenance performance.
The connection method can be selected from a screw terminal and a PUSH-IN fastening terminal.
High speed sampling of 50ms is realized.
Easy to connect with PLC through no program communication.
The use of electric communication conversion Village (sold separately) connected to the computer after,
No power connection can be set E5AN-HTAA2HH03BD-FLK.
It can be easily set by CS-Thermo (sold separately). The main body: terminal type, temperature input type.
Type: control output 1 point type (power AC/DC24V).
Shell color: black.
Control output: relay output.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater with broken wire, SSR fault, heater over current detection function /ES1B power supply: single phase heater with detection function.
Event entry point: 2.
Transfer output: -.
Communication: -.
48mm general thermostat has been upgraded & function / performance upgrade.
Indicates that the accuracy is increased and the preventive maintenance function is increased,
Furthher performance improvement E5AN-HTAA2HH03BD-FLK.
E5CN-U (insert type) add analog input and current output type.
Add PV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactivee display PV/SV E5AN-HTAA2HH03BD-FLK.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.


...More relevant models >>>>