LK Automation Limited LK Automation Limited
Brand: OMRON
Go Back >> Product Catalogues
E5AN-HTAA2HBD Programmed temperature controller
OMRON E5AN-HTAA2HBD Manual And Instructions
E5AN-HTAA2HBD datasheetPDF datasheet
E5AN-HTAA2HBD Programmable TypeUser's Manual
E5AN-HTAA2HBD Programmable TypeBasic Type
E5AN-HTAA2HBD Basic Type
E5AN-HTAA2HBD Basic TypeBasic Type
E5AN-HTAA2HBD User's Manual
E5AN-HTAA2HBD User's Manual
E5AN-HTAA2HBD Communications FunctionsUser's Manual
E5AN-HTAA2HBD INSTRUCTION Manual
E5AN-HTAA2HBD INSTRUCTION Manual

OMRON E5AN-HTAA2HBD Product information and technical parameters:
Brand: OMRON
Name: Programmed temperature controller
Model: E5AN-HTAA2HBD
Size: 96 x 96mm.
Type: power AC/DC24V with.
Shell color: black.
Control output 1: output unit mode.
Control output 2: output unit mode.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater break, SSR fault detection function: single phase heater detection function.
Event entry point: 2.
Transfer output: -.
Remote SP:4 to 20mA input.
Communication: -.
New program type.
A new type of liquid crystal with high performance cost ratio is adopted in the 256 paragraph,
Visual angle, contrast can be improved.
Can be set up to 8 procedures (mode) x 32 (step) procedure.
High resolution 5 bit display / can display 0.01 degrees C.
High speed sampling period 60ms.
All models complete a variety of (to the thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors.
Also supports remote SP.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/RESET, alarm), interactive display PV/SV.
Through the support software (Ver.4.3 CX-Thermo) makes the process of setting management becomes very
Simple use of simple computing functions (AND/OR logic and delay) to set the implementation of flexible contact output.
Through the infrared port can be carried out from the front of the communication.
The control output ON/OFF times counting function can predict the fault of the internal relay of the temperature controller.

Protective tubing diameter: D = 8.0.
Sleeve diameter Sleeve length: d = 11mm, l = 55mm.
tube thickness: 0.8 mm.
Lead wire length: 0.5m.
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work E5AN-HTAA2HBD.
Ideal for the thermal input devices of Temperature Controllers.
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal E5AN-HTAA2HBD Protective tubing length: 200mm.
Lead wire length: 1m.
Element type: J (IC).
A Wide Variety of High-precision.
Temperature Sensors E5AN-HTAA2HBD.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work.
Ideal for the thermal input devices of Temperature Controllers.
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal. The main body: terminal type, temperature input type E5AN-HTAA2HBD.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output: relay output.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater with broken wire, SSR fault, heater over current detection function /ES1B power supply: ES1B power supply.
Event input points: -.
Transfer output: -.
Communication: RS-485.
48mm general thermostat has been upgraded & function / performance upgrade.
Indicates that the accuracy is increased and the preventive maintenance function is increased,,
Further performance improvement E5AN-HTAA2HBD.
E5CN-U (insert type) add analog input and current output type.
Add PV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactivee display PV/SV E5AN-HTAA2HBD.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.


...More relevant models >>>>