LK Automation Limited LK Automation Limited
Brand: OMRON
Go Back >> Product Catalogues
E5AC-TRX4DSM-060 Digital temperature controller program
OMRON E5AC-TRX4DSM-060 Manual And Instructions
E5AC-TRX4DSM-060 datasheetPDF datasheet
E5AC-TRX4DSM-060 datasheetPDF datasheet
E5AC-TRX4DSM-060 RS-485 CompoWay/FInstructions Manual
E5AC-TRX4DSM-060 User's Manual
E5AC-TRX4DSM-060 User's Manual
E5AC-TRX4DSM-060 INSTRUCTION Manual

OMRON E5AC-TRX4DSM-060 Product information and technical parameters:
Brand: OMRON
Name: Digital temperature controller program
Model: E5AC-TRX4DSM-060
Size: 96 x 96mm.
Control output 1: relay.
Auxiliary (alarm) output: 4.
Transfer output: -.
Event input: -.
Communication: -.
Break detection: -.
Power supply voltage: DC24V/AC24V.
E5 - C series of new products program.
Maximum 256 segment of the program capacity,
Support for multiple applications.
Can be set up to 8 procedures (mode) x 32 (step) procedure.
The use of high 25mm (E5AC-T), 18mm (E5AC-T) PV display (white),
Improve visibility.
Not only on the top of the body, but also on the front,
The use of communication adapter cable (sold separately) connected to the computer after,
No power connection can be set.
It can be easily set by CX-Thermo (sold separately).
High speed sampling to achieve 50ms.
With auxiliary output (4 points), event input (maximum 6 points), the transmission output,
Support a variety of applications.
Slender fuselage depth 60mm.
Easy to connect with PLC through no program communication.
Combined temperature control device through component communication.
Add position proportional control type, also support control valve control.

Size: 48 * 48mm, terminal type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output: current output.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater break, SSR fault detection function: -.
Event input points: -.
Transfer output: output (using control output) E5AC-TRX4DSM-060.
Communication: -.
New program type.
A new type of liquid crystal with high performance cost ratio is adopted in the 256 paragraph,
Visual angle, contrast can be improved E5AC-TRX4DSM-060
Can be set up to 8 procedures (mode) x 32 (step) procedure.
High resolution 5 bit display / can display 0.01 degrees C (to achieve a small size of 48 x 48mm).
High speed sampling period 60ms E5AC-TRX4DSM-060.
Full of all models (capable of thermocouple /Pt/ analog input switching),
1 machines to support a variety of sensors.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/RESET, alarm),
Interactive display PV/SV.
By supporting software (Ver.4.3 CX-Thermo),
In simple arithmetic functions (AND/OR logic and delay).
Setting the program settings that can perform flexible contact output E5AC-TRX4DSM-060.
The control output ON/OFF times counting function can predict the fault of the internal relay of the temperature controller. Size: 48 x 48mm.
Control output 1: voltage output (SSR driver).
Control output 2: voltage output (SSR driver).
Auxiliary output: 3 points (common universal).
Power supply voltage: AC/DC24V.
Terminal type: screw terminal table type.
Input category: full range multi input.
Heater break, SSR fault detection function: -.
Communication: RS-485.
Event input: 2 points.
Remote SP input: -.
Transfer output: -.
Using large font PV display (white), improve visibility.
Selection, operation and setting.
Functional performance of input and output points.
Support for more extensive range of applications.
Using high PV 15.2mm display (white), improve visibility.
High speed sampling to achieve 50ms.
With auxiliary output (maximum 3 points), event input (maximum 4 points), the transmission output,
Remote SP input function, support for a variiety of applications E5AC-TRX4DSM-060.
E5CC 60mm has a depth of slender body.
The use of communication adapter cable (sold separately) connected with a computer.
After that, no power supply connection can be set.
It can be easily set by CX-Thermmo (sold separately) E5AC-TRX4DSM-060.
Easy to connect with PLC through no program communication.
Combined temperature control device through component communication.


...More relevant models >>>>