Terminal type: Exposed-lead Models.
Protective tubing diameter D(mm): 4.8 dia.
Protective tubing length L: 50 cm.
Lead wire type: Heat resistive.
Lead wire length M: 1m.
A Wide Variety of High-precision.
Temperature Sensors.
by new models with ferrules to help reduce wiring work.
Ideal for the thermal input devices of Temperature Controllers.
and also according to the type and shape of the terminal.
Size: DIN 1/16, 48 X 48 x 60mm.
Power supply voltage: AC100 ~ 240V.
Input type: thermocouple.
Alarm points: 1 points.
Control output: voltage output (for driving SSR).
Simple new temperature controller, easy to achieve temperature control.
Good visibility (character height E5CSL:21.7mm, E5CWL:16.2mm (PV), E5EWL:20mm (PV)) E52-CA50AF D=4.8 NETU 1M.
From the front panel depth: 60mm.
Parameter is less, set simple
E52-CA50AF D=4.8 NETU 1M
Sampling time was reduced to 250ms. Size: 96 × 96 mm.
Control type: 2-loop control.
Control mode: 2-loop standard control, 2-loop heating and cooling control,
Single-loop cascade control, Single-loop control with remote SP,
Single-loop proportional control.
Outputs(control/transfer): 4 points: Pulse voltage (2 points) and
Pulse voltage/current (2 points) E52-CA50AF D=4.8 NETU 1M.
Optional functions: Auxiliary outputs (SUB), 4;
Event inputs, None; Serial communications, Yes.
E5AR Digital Controllers offer high speed,
high precision, and multiple I/O and use a 5-digit,
3-row LCD display for high visual clarity.
A short sampling period of 50 ms enables use in applications,
requiring high-speed response.
PV, SP, and MV data is displayed simultaneously in a 3-row,
negative LCD display with a backlight E52-CA50AF D=4.8 NETU 1M.
Multiloop control, cascade control, and proportional control are,
possible with a single Controller.
When using models with CompoWay/F communications, initial,
settings can be downloaded and settings can be masked using,
Support Software (CX-Thermo version 4.0 or higher).
Equipped with calculation functions as a standard (e.g., square,
root calculation and broken-line approximation).
DeviceNet Communications.
Data setting and monitoring can be performed without special programming. Size: 48 x 96mm.
Ontology: terminal type, temperature input type.
Category: control output 2 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output 1: relay output.
Control output 2: voltage output (SSR driver).
Control mode: standard or heating cooling.
Auxiliary output points: 3 points.
A power supply for the detection of /ES1B fault, SSR fault and heater over current for heater use.
Event input points: -.
Transfer output: -.
Communication: -.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of /.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manuall, RUN/STOP, alarm), interactive display PV/SV E52-CA50AF D=4.8 NETU 1M.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Increased the 3 segment display, which cann display the current value / target / operation E52-CA50AF D=4.8 NETU 1M.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc., can be a key operation.