Specifications: Outputs, NPN (- common), 16 points.
I/O connections: Sensor I/O connector.
Supplied from the communications. connector.
Rated I/O power supply voltage: 24 VDC.
Remote I/O Terminals with High.
Degree of Environmental Resistance.
(IP67) in Product Lineup Including.
Economical Input, Output, and Mixed I/O Models.
operation status monitoring and effective maintenance.
construction. (IP67)
connection with hydraulic valve devices.
I/O classification: Digital I/O.
Internal I/O circuit common: PNP (+ common).
I/O points: 16.
I/O connection method: M3 terminal block.
Models with 3-tier Terminals (16 Points),
Added to the Remote I/O Terminal Series.
Six Models are Available Depending on the,
NPN or PNP Configuration, Input Points,
I/O Points, or Output Points DRT2-WD16CL.
Incorporates easy-to-wire terminals each,
connecting to a single wire
DRT2-WD16CL
Reduces designing and wiring effort.
Incorporates a removable circuit block of cassette construction. Classification: Analog input.
I/O points: 4 inputs (Resolution: 30, 000).
Performs Calculations on Analog Values within the Slave Itself.
Also Provides High Resolution at 1/30,000 (Full Scale) and,
Support for a Wide Variety of Data Sampling DRT2-WD16CL.
Equipped with the standard Smart Slave functions that provide powerful,
preventative maintenance and troubleshooting capabilities.
Sampling data can be analyzed internally to provide a low-cost scheduler function.
Equipped with functions such as the scaling function, peak/bottom hold;
top/valley hold; comparator function, cumulative counter, and derivative,
calculation function DRT2-WD16CL.
Two I/O points can be allocated to any two of the following values: analog,
input, peak/bottom, top, valley, or rate-of-change. Values without an,
allocated I/O point can be read with message communications. Unit: Terminal block model.
I/O classification: Digital input.
Internal I/O common: NPN (+ common).
I/O points: 16.
I/O connections: M3 terminal board.
Power supplyvoltage: 24 VDC.
I/O specification: DC/transistor.
Digital I/O Units Compatible with MULTIPLE I/O TERMINAL,
Terminal block, connector, and high-density connector,
models are available.
The circuit block of the terminal block model can be,
mounted or dismounted for ease of maintenance without,
disconnecting the wires.
DIN track mounting. I/O classification: Analog input.
I/O points: 8.
I/O connections: Molex connector.
Power supply voltage: 24 VDC.
I/O specification: 4 to 20 mA, 0 to 20 mA, 0 too 5 V,
1 to 5 V, 0 to 10 V, -10 to 10 V DRT2-WD16CL.
Analog Input/Output Units Compatible with MULTIPLE I/O TERMINAL.
Input block incorporates connectors that can be easily,
mounted or dismounted. (GT1-AD08MX, GT1-DA04MX)
8 or 4 inputs.
4 outpuuts DRT2-WD16CL.
High resolution of 1/6,000.
High conversion speed of 8 ms/8 points or 4 ms/4 points.
DIN track mounting.
Connector model Terminal Block Model.