Specifications: Outputs; PNP (+ common); 16 points.
I/O connections: M3 Screw terminals.
Supplied from the communications connector.
Rated I/O power supply voltage: 24 VDC.
Allows I/O Expansion with Transistor Terminals.
of the control system.
on the communications power supply.
and equipment operating information.
Expansion via Expansion I/O Units.
maintenance is easier.
Specifications: Outputs;
PNP (+ common);
16 points.
I/O connections: MIL connector(Connector with 10-cm cable).
Rated internal circuit power supply voltage:
Supplied from the communications connector.
Rated I/O power supply voltage: 24 VDC.
Very Compact 16-/32-point Remote Terminals.
Used in combination with Interface,
Conversion Boards (e DRT2-OD16-1. g., D-Sub) to,
connect to a wide range of interfaces
DRT2-OD16-1
35 x 60 x 80 mm (W x D x H). Name: Three-tier Screw Terminal Block.
Specifications: Outputs; 8 outputs; NPN;
With Short-circuit and,
Disconnected Line Detection.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced DRT2-OD16-1.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on site.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error. Name: Screw Terminal Block with Relay Outputs DRT2-OD16-1.
Specifications: Outputs;
8 outputs; Contacts.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on site.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error. I/O classification: Analog input.
I/O points: 4.
I/O connections: Terminal block.
Power supply voltage: 24 VDC.
I/O specification: 4 to 20 mA, 0 to 20 mA, 0 too 5 V,
1 to 5 V, 0 to 10 V, -10 to 10 V DRT2-OD16-1.
Analog Input/Output Units Compatible with MULTIPLE I/O TERMINAL.
Input block incorporates connectors that can be easily,
mounted or dismounted. (GT1-AD08MX, GT1-DA04MX)
8 or 4 inputs.
4 outpuuts DRT2-OD16-1.
High resolution of 1/6,000.
High conversion speed of 8 ms/8 points or 4 ms/4 points.
DIN track mounting.
Connector model Terminal Block Model.