LK Automation Limited LK Automation Limited
Brand: OMRON
Go Back >> Product Catalogues
D4SL-N4NFA-D4 Guard Lock Safety-door Switch/D4SL-N-mounting Slide Key
OMRON D4SL-N4NFA-D4 Manual And Instructions
D4SL-N4NFA-D4 datasheetPDF datasheet
D4SL-N4NFA-D4 INSTRUCTION sheet

OMRON D4SL-N4NFA-D4 Product information and technical parameters:
Brand: OMRON
Name: Guard Lock Safety-door Switch/D4SL-N-mounting Slide Key
Model: D4SL-N4NFA-D4
Release Key Type: Special (resin).
Wiring method: Terminal block.
Solenoid voltage/Indicator: 24VDC (Orange).
Lock and release type: Mechanical lock Solenoid release.
Contact configuration (door open/closed detection switch,
and lock monitor switch contacts): 6-contact Model,
Insert the built-in switch (N, P, Q or R) into the blank @.
Conduit size (See Note.): M20.
World''s smallest Class 6-contact Guard Lock.
Safety-door Switch.
.
Wiring time is reduced with two types of wiring.
methods capable of one-touch attachment and removal.
A wide variety of built-in switches can be used for various devices.
(4-, 5-, and 6-contact models are available).
Key holding force of 1,300 N.
It is possible to change the key insertion point.
without detaching the head.
Drive solenoids directly from the Controller.
.
Lockout Key to prevent workers from becoming.
trapped inside the hazardous area.
The vertical D4SL Guard Lock Safety-door Switch,
can be easily mounted on 40 × 40 mm aluminum frames.
The plastic material makes the Slide Key suitable,
for lightweight doors.

Safety outputs *1: Instantaneous, 2; OFF-delayed*2, 2 (Semiconductor).
Auxiliary outputs *2: 2(Semiconductor).
No. of input channels: 1 or 2 channels.
Max. OFF-delay time *1: 15 s.
Rated voltage: 24 VDC.
Terminal block type: Screw terminals.
Logical AND Function Adds Flexibility to I/O Expansion D4SL-N4NFA-D4.
Facilitates partial or complete control system setup.
Solid-state outputs (excluding Expansion Units) D4SL-N4NFA-D4
Detailed LED indications enable easy diagnosis.
TÜV SÜD certification for compliance,
with IEC/EN61508 (SIL3), EN ISO13849-1 (PLe/Safety Category 4).
Approved by UL and CSA.
New unit joins the Series with the following two additional features:
-OFF-delay time of up to 150 seconds can be set D4SL-N4NFA-D4.
-Two logical AND connection inputs. Achieve Safety Control through,
Programming.
Compact Safety Controller.
The NE1A-SCPU01-V1 provides 16 built-in safety inputs,
and 8 built-in safety outputs.
The NE1A-SCPU02 provides 40 built-in safety inputs and,
8 built-in safety outputs.
Reduced wiring with safety networks. Connect up to 32,
Safety Terminals.
Monitor the safety system from Standard Controllers,
across the network D4SL-N4NFA-D4.
ISO13849-1 (PLe) and IEC 61508 SIL3 certification. Number of beams: 80.
Protective height: 1600mm.
Safety Light Curtains with Durable,
Impact-resistant Body and Long,
20-m Sensing Distance.
MS/MSF4800A Advanced Series.
Programming and Diagnostics Module (PDM) makes it easy,
to set functions.
Series connection is possible only with the MSF4800A.
Blanking can be set.
Muting is possible only with the MSF4800A by using the,
MS4800-RM6 Resource Module.
MS/MSF4800B Basic Series,
Features all necessary basic Safety Light Curtain functions.
Series connection is possible only with the MSF4800B.
Programming and Diagnostics Module (PDM) makes it easy,
to set functions. Number of beams: 56.
Protective height: 1680mm.
Safety Light Curtains with Durable,
Impact-resistant Body and Long,
20-m Sensing Distance.
MS/MSF4800A Advanced Series.
Programming and Diagnostics Module (PDM) makes it easy,
to set functionss D4SL-N4NFA-D4.
Series connection is possible only with the MSF4800A.
Blanking can be set.
Muting is possible only with the MSF4800A by using the,
MS4800-RM6 Resource Module.
MS/MSF4800B Basic Series,
Features all necessary basic Safety Lightt Curtain functions D4SL-N4NFA-D4.
Series connection is possible only with the MSF4800B.
Programming and Diagnostics Module (PDM) makes it easy,
to set functions.