Unit type: CS1 Basic I/O Units.
Product name: Triac Output Units.
Specifications: 250 VAC, 0.5 A max.
16 outputs.
C200HX/HG/HE Expansion I/O Rack, No.
SYSMAC BUS Slave Rack, No.
Words required: 1 word.
Current consumption: 5V system, 0.23 max.
26 V system, --.
Standards: UC, N, L, CE.
Highly Reliable Process Control.
Name: CS1D CPU Unit for Single CPU Systems.
Specifications: Number of I/O points,
5,120 points (7 Racks);
Program capacity, 250 Ksteps;
Data Memory, 448 Kwords(DM: 32 Kwords,
EM: 32 Kwords×13 banks);
LD execution time, 0.02 μs;
Duplex CPUs, --;
Interrupt functions, OK.
Current consumption: 5V system, 0 CS1W-OA211. 82A;
26V system, --.
Standards: UC1, N, L, CE.
Redundant CPU Units , Power Supply Units ,
Communications Units ,
and Expansion I/O Cables
CS1W-OA211
Coaxial.Unit type: CS1 CPU Bus Unit.
Product name:SPU Unit,
(High-speed Data Storage Unit).
Specifications: PC Card slot,
1 PC Card Type II slot Insert an,
OMRON HMC-EF@@@ to use the Memory Card;
Ethernet (LAN) port, 1 port(10/100BASE-TX) CS1W-OA211.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.56A; 26V, --.
Standards: UC1, CE.
High-speed Collection of System Data.
The CPU Unit can collect large amounts,
of process data, operation data,
inspection data, and other controlled system,
data quickly and automatically save the data,
in external storage media as CSV files. Unit type: CS1 Special I/O Units.
Product name: Isolated-type,
Thermocouple Input Units CS1W-OA211.
points Input: 4 inputs.
Signal range selection:
Set separately for each input.
I/O type: B, E, J, K, N, R, S, T, ±80mV.
Conversion speed: 150 ms/4 inputs.
Externa connection: Removable erminal block.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.15A; 26V, 0.15A.
Standards: UC1, CE.
Provides the functionality of isolators,
power supplies, signal converters,
and other devices.
The Analog Input Unit converts analog,
input signals such as 1 to 5 V or 4 to 20mA,
into digital values, and takes the values,
scaled in industrial units, and transfers,
it to the CPU Unit as the process value.
Because of this, no ladder program is required,
at the CPU Unit for scaling.
The Analog Output Unit converts analog output set,
values from the CPU Unit to analog output signals,
such as 4 to 20 mA or 1 to 5 V, and outputs them.
The built-in functions, such as measurement value,
alarms, rate-of-change calculations, and square roots,
have enabled major savings in costt and space compared,
with previous systems CS1W-OA211.
High-resolution Models and 8-point Input Models are,
also available.
By combining the Units, logging/monitoring.
systems can be constructed,
or the Units can be used together with LCBs/LCCUs,
to construct complete process control systems CS1W-OA211.
Parameters can be easily displayed and set in an,
easy-to-understand form without special tools.