Product name: CS1 CPU Backplane.
Units cannot be mounted; 10 slots.
Appli cable CPU Unit: CS1 CPU Unit.
C200H Group-2 High density I/O Unit, Yes.
Yes; C200H series Special I/O Unit, Yes.
CPU Bus Units: CS-series CPU Bus Unit, Yes.
26 V system, --.
Standards: U, C, N, L, CE.
Highly Reliable Process Control.
Product name: CS1 CPU Backplane.
Specifications: For CS-series,
Unit only Note: C200H series,
Units cannot be mounted; 10 slots.
Appli cable CPU Unit: CS1 CPU Unit.
Basic I/O Units: CS-series Basic I/O Unit,
Yes; C200H series Basic I/O Unit, No;
C200H Group-2 High density I/O Unit, No.
Special I/O Units: CS-series Special I/O Unit,
Yes; C200H series Special I/O Unit, No CS1W-BC103.
CPU Bus Units: CS-series CPU Bus Unit, Yes
CS1W-BC103
Current consumption: 5V system, 0.11A;
26 V system, --.
Standards: U, C, N, L, CE.
Multi-application Controllers:
From High-performance Machine C,
Highly Reliable Process Control. Unit type: CS1 Basic I/O Units.
Product name: Relay Output Units.
Specifications: 12 to 24 VDC,
0 CS1W-BC103. 5A . 16 outputs; Sinking.
Mountable Racks: CPU Rack, CS1W-BC,
@@3, Yes, @@2, Yes;
C200HX/HG/HE Expansion I/O Rack, No.
CS1 Expansion Rack, CS1W-BI,
@@3, Yes, @@2, Yes;
CS1 Long distance Expansion Rack, Yes;
SYSMAC BUS Slave Rack, No.
Words required: 1 word.
Current consumption: 5V system, 0.17A;
26 V system, --.
Standards: UC1, N, L, CE.
Multi-application Controllers:
From High-performance Machine C,
Highly Reliable Process Control CS1W-BC103. Type: Counter inputs, pulse outputs.
12 DC inputs: Yes.
Counter inputs: 2.
Analog inputs: None.
8 transistor outputs: Yes.
2 pulse outputs: No.
2 analog outputs: Yes.Unit type: CS1 Special I/O Units.
Product name: Isolated-type,
Thermocouple Input Units.
points Input: 4 inputs.
Signal range selection:
Set separately for each input.
I/O type: B, E, J, K, L, N, R, S,
T, U, WRe5-26, PLII, ±100 mV.
Conversion speed: 20 ms/4 inputs,
10 ms/2 inputs.
Externa connection: Removable erminal block.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.12A; 26V, 0.08A.
Standards: UC1, N, CE.
Provides the functionality of isolators,
power supplies, signal converters,
and other devices.
The Analog Input Unit converts analog,
input signals such as 1 to 5 V or 4 to 20mA,
into digital values, and takes the values,
scaled in industrial units, and transfers,
it to the CPU Unit as the process value.
Because of this, no ladder program is required,
at the CPU Unit for scaling.
The Analog Output Unit converts analog output set,
values from the CPU Unit to analog output signals,
such as 4 to 20 mA or 1 to 5 V, and outputs them.
The built-in functions, such as measurement value,
alarms, rate-of-change calculations, and square roots,
have enabled major savings in costt and space compared,
with previous systems CS1W-BC103.
High-resolution Models and 8-point Input Models are,
also available.
By combining the Units, logging/monitoring.
systems can be constructed,
or the Units can be used together with LCBs/LCCUs,
to construct complete process control systems CS1W-BC103.
Parameters can be easily displayed and set in an,
easy-to-understand form without special tools.