LK Automation Limited LK Automation Limited
Brand: OMRON
Go Back >> Product Catalogues
CJ1W-PDC15 Process Analog I/O Unit
OMRON CJ1W-PDC15 Manual And Instructions
CJ1W-PDC15 datasheetPDF datasheet
CJ1W-PDC15 for NJ-series CPU UnitPROGRAMMING MANUAL
CJ1W-PDC15 Installation Guide

OMRON CJ1W-PDC15 Product information and technical parameters:
Brand: OMRON
Name: Process Analog I/O Unit
Model: CJ1W-PDC15
Unit classification: CJ1 Special I/O Units.
Product name: Isolated type DC Input Units.
Input points: 2 inputs.
Signal range selection: DC voltage:
0 to 1.25 V, -1.25 to 1.25 V, 0 to 5 V,
1 to 5 V, -5 to 5 V, 0 to 10 V, -10 to 10 V,
±10 V selectable range DC current:
0 to 20 mA, 4 to 20 mA.
Conversion speed (resolution): Conversion,
speed: 10 ms/2 inputs, Resolution: 1/64,000.
Accuracy at ambient temperature of 25°C:
Accuracy: (±0.05% of F.S.
External connection: Removable terminal block.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.18A; 24V, 0.09A.
Standards: UC1, CE.
A Single Unit Handling All Types of Inputs,
such as Temperature Sensor Inputs and,
Analog Signal Inputs (e.g., 4 to 20 mA or 1 to 5V).
A Unit supports four input channels,
each of which can be set to a
platinum resistance thermometer, thermocouple,
and DC signal (current, voltage).
All inputs are isolated.

Type: CJ1 Special I/O Unit.
Connected ID System: V680 Series; 1 Head.
External power supply: --.
No. of unit numbers used: 1 unit number.
Current consumption: 5V, 0.26A;
24V, 0.13A; External, --.
Communication Unit Dedicated for RFID V680,
Allowing Direct Connection to OMRON PLC CJ/
CS/NJ-series CJ1W-PDC15.
Communication unit for connecting RFID V680-series,
which can be used around the world, directly to PLC CJ1W-PDC15
Allows batch transfer of data up to 32 kbytes. A Wide Range of Basic Input,
Units for High Speed Input and,
Different Applications.
Receive ON/OFF signals from external,
devices into the PLC System to update,
I/O memory in the CPU Unit.
New high-speed input models CJ1W-ID212 and,
CJ1W-ID233 are now available CJ1W-PDC15. These units can,
help to increase system throughput. I/O capacity/Mountable Units(Expansion Racks): 2, 560 points/40 Units (3 Expansion Racks max.).
Program capacity: 120K steps.
CJ1H-CPU66H Data memory capacity: 256K words(DM: 32K words, EM: 32K words × 7 bank).
LD instructioProduct name: CJ2M CPU Units.
Specifications: I/O capacity/Mountable Units(Expansion Racks),
2, 560 points/40 Units(3 ExpansionRacks max CJ1W-PDC15. );Programcapacity,
10K steps;Data memorycapacity, 64K words,
(DM: 32K words, EM: 32K words ×1 bank);
LD nstruction execution time, 0. 04 μs;
EtherNet/IP function: --;
Option board slot: --.
Current consumption (A): 5V, 0. 7(See note. );24V, --.
Standards: UC1, N, L, CE.
CJ2M for basic machine automation.
The CJ2M Series is ideal for packaging and general.
machine automation needs. Connectivity is assured.
thanks to the built-in USB port and the choice of.
Ethernet and RS-232C/422/485 interfaces on the CPU. Unit type: CJ1 Basic I/O Units.
Product name: Interrupt Input Unit.
Specifications: I/O points, 16 inputs;
Input voltage current, 24 VDC, 7mA;
Commons: 16 points, 1 common;
Input pulse widt conditions, ON time:
0.05 ms max. OFF time: 0.5 ms max;
Max. Units mountable per Unit, 2;
External connection, Removable terminal block.
No. of words allocated: 1 word.
Currennt consumption: 5V, 0 CJ1W-PDC15. 08A; 24V, --.
Standards: UC1, N, L, CE.
High-speed Starting of I/O InterruptTasks.
Use Up to Two Units for a Total of Up,
to 32 Interrupt Inputs.
Receive inputs to start I/O interrupt tasks.
When the Interruptt Input Unit receives an input,
the CPU Unit will interrupt execution of the,
cyclic tasks in the normal CJ1W-PDC15.
program and execute an I/O interrupt task.


...More relevant models >>>>
Last one: OMRON CJ1W-PTS16