CJ1W-OD204 Output Units
OMRON CJ1W-OD204 Manual And Instructions
CJ1W-OD204 datasheetPDF datasheet
CJ1W-OD204 HardwareOPERATION MANUAL

OMRON CJ1W-OD204 Product information and technical parameters:
Brand: OMRON
Name: Output Units
Model: CJ1W-OD204
Unit type: CJ1 Basic I/O Units.
Product name: Transistor Output Units.
Specifications: Output type, Sourcing;
I/O points, 8 outputs;
Maximum switching capacity, 24VDC,
0.5A Short-circuit protection;
Commons, 8 points, 1 common;
External connection, Removable terminal block.
No. of words allocated: 1 word.
Current consumption: 5V, 0.10A; 24V, --.
Standards: UC1, N, L, CE.
A Wide Range of Basic Output,
Units for High Speed Output,
and Different Applications.
These Output Units receive the ,
results of output instructions ,
from the CPU Unit and perform ON/OFF,
control for external devices.
High-speed Output models CJ1W-OD213 and,
CJ1W-OD234 can help to increase system.
throughput.

Unit classification: CJ1 Special I/O Units.
Product name: Process Input Units,
(Isolated type Units with Universal Inputs).
Input points: 4 inputs.
Signal range selection:
Set separately for each input.
Signal range:Fully universal
inputs: Pt100, JPt100, Pt1000, K,
J, T, L, R, S, B, 4 to 20 mA, 0 to 20 mA,
1 to 5 V, 0 to 5 V, 0 to 10 V CJ1W-OD204.
Conversion speed (resolution): Conversion,
speed: 250 ms/4 inputs CJ1W-OD204
Accuracy at ambient temperature of 25°C:
Accuracy: Platinum resistance thermometer,
input: ±0.3% of PV or ±0.8°C, whichever,
is larger) ±1 digit max. Thermocouple input:
(±0.3% of PV or ±1.5°C, whichever is larger),
±1 digit max. *1 Voltage or current input:
±0.3% of F CJ1W-OD204. S. ±1 digit max.
External connection: Removable terminal block.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.32A; 24V, --.
Standards: UC1, L, CE.
A Single Unit Handling All Types of Inputs,
such as Temperature Sensor Inputs and,
Analog Signal Inputs (e.g., 4 to 20 mA or 1 to 5V).
A Unit supports four input channels,
each of which can be set to a
platinum resistance thermometer, thermocouple,
and DC signal (current, voltage) CJ1W-OD204.
All inputs are isolated. Product name: CJ-series I/O Control Unit.
Specifications: One I/O Interface Unit is,
required on each Expansion Rack.
Connecting Cable: CS1W-CN@@3 Expansion,
Connecting Cable Mount to the right of,
the Power Supply Unit.
Current consumption: 5V , 0.02A;
24V, --.
Standards: UC1, N, L, CE.
Expand CJ/NJ-series with These Units.
To expand a CJ/NJ-series Controller,
connect an I/O Control Unit to the CPU Rack,
and I/O Interface Unit to the Expansion Rack,
and connect the two Units with I/O Expansion Cable. Product name: CJ2H (Built-in EtherNet/IP) CPU Units.
Specifications: I/O capacity/Mountable Units(Expansion Racks),
2,560 points/40 Units(3 Expansion Racks max.) ;
Program capacity, 100K steps; Data memory capacity,
160K wordss(DM: 32K words, EM: 32K words × 4 bank);
LD nstructio execution time, 0 CJ1W-OD204. 016 μs.
Current consumption(A): 5V,0.82(See note.); 24v, --.
Standards: UC1, N, L, CE.
CJ2H for high speed, high capacity.
The CJ2H Series is ideal for advannced machine CJ1W-OD204.
automation needs such as those required in image.
processing inspection of electrical components and,
high speed sorting on conveyors.