Unit type: CJ1 Basic I/O Units.
Product name: DC Input Units.
Removable terminal block; No. of words allocated, 1 word.
Current consumption: 5V, 0.13A; 24V, --.
Standards: N, L, CE.
Different Applications.
I/O memory in the CPU Unit.
CJ1W-ID233 are now available. These units can,
help to increase system throughput.
Unit type: CJ1 Special I/O Units.
Product name: Analog Input Unit.
I/O points: 4 inputs;
Signal range selection: Set separately for each input.
Signal range; Resolution: 1 to 5 V (1/10,000),
0 to 10 V (1/20,000), -5 to 5 V (1/20,000),
-10 to 10 V (1/40,000), and 4 to 20 mA (1/10,000).
Conversion period: 20 μs/1 point, 25 μs/2 points,
30 μs/3 points, 35 μs/4 points,
The Direct conversion is provided CJ1W-ID212
CJ1W-ID212
Accuracy at ambient temperature of 25°C:
Voltage: ±0.2% of F.S. Current: ±0.4% of F.S.
External connection: Removable terminal block.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.52A; 24V, --.
Standards: UC1, CE.
Consistent Microsecond Throughput:
Models with Direct Conversion Join the Lineup CJ1W-ID212.
Analog Input Units for converting analog input,
signals into binary data.
Analog Output Units for converting binary ,
data into analog output signals.
Product name: CJ1M CPU Units; Without built-in I/O.
Specifications: I/O capacity/Mountable Units Expansion Racks),
640 points/20 Units(1 Expansion Racks max.) ; Program capacity,
20K steps; Data memory capacity, 32K words(DM: 32K words, EM: None);
LD nstruction execution time, 0 CJ1W-ID212. 1 μs.
Current consumption: 5v, 0.58A (Seenote 1.) ; 24V,--.
Standards: UC1, N, L, CE.
Versatile Machine Control with the,
Highest Performance Standards in the Industry. Unit classification: CJ1 Special I/O Units.
Product name: Isolated type DC Input Units.
Input points: 2 inputs.
Signal range selection: DC voltage:
0 to 1.25 V, -1.25 to 1.25 V, 0 to 5 V,
1 to 5 V, -5 to 5 V, 0 to 10 V, -10 to 10 V,
±10 V selectable range DC current:
0 to 20 mA, 4 to 20 mA.
Conversion speed (resolution): Conversion,
speed: 10 ms/2 inputs, Resolution: 1/64,000.
Accuracy at ambient temperature of 25°C:
Accuracy: (±0.05% of F.S.
External connection: Removable terminal block.
No. of unit numbers allocated: 1 CJ1W-ID212.
Current consumption: 5V, 0.18A; 24V, 0.09A.
Standards: UC1, CE.
A Single Unit Handling All Types of Inputs,
such as Temperature Sensor Inputs and,
Analog Signal Inputs (e.g., 4 to 20 mA or 1 to 5V).
A Unit supports four inpuut channels,
each of which can be set to a
platinum resistance thermometer, thermocouple,
and DC signal (current, voltage) CJ1W-ID212.
All inputs are isolated.