Unit type: CJ1 Special I/O Units.
Product name: Analog Output Unit.
Set separately for each output.
4 to 20 mA; 1/4,00.
Conversion period: 1 ms/point.
Voltage: ±0.3% of F.S. Current: ±0.5% of F.S.
External connection: Removable terminal block.
External power supply: 24 VDC +10% -15%, 140mA max.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.12A; 24V, 0.14*3.
Standards: UC1, N, L, CE.
Models with Direct Conversion Join the Lineup.
signals into binary data.
data into analog output signals.
Unit classification: CJ1 Special I/O Units.
Product name: Temperature Control Units.
Specifications; No. of loops: 2 loops,
heater burnout detection function;
Temperature sensor inputs: Thermocouple,
input (R, S, K, J, T, B, L);
Control outputs: Open collector,
NPN outputs (pulses).
No. of unit numbers allocated: 2 CJ1W-DA021.
Current consumption: 5V, 0.25A; 24V, --.
Standards: UC1, N, L, CE
CJ1W-DA021
A Single Unit Performing All the Functions of,
4 Temperature Controllers.
A Special I/O Unit with direct input,
of thermocouple or resistance thermometer,
PID control with 2 degrees of freedom,
and open collector output. Unit type: CJ1 Basic I/O Units.
Product name: Transistor Output Units CJ1W-DA021.
Specifications: Output type, Sourcing;
I/O points, 32 outputs;
Maximum switching capacity, 24VDC,
0.5A Short-circuit protection;
Commons, 16 points, 1 common;
External connection, MIL connector.
No. of words allocated: 2 words.
Current consumption: 5V, 0.15A; 24V, --.
Standards: UC1, N, L, CE.
A Wide Range of Basic Output,
Units for High Speed Output,
and Different Applications CJ1W-DA021.
These Output Units receive the ,
results of output instructions ,
from the CPU Unit and perform ON/OFF,
control for external devices.
High-speed Output models CJ1W-OD213 and,
CJ1W-OD234 can help to increase system.
throughput. Unit type: CJ1 Basic I/O Units.
name: B7A Interface Units.
Specifications: I/O points, 64 inputs;
External connection, Removable terminal block.
No. of words allocated: 4 words.
Current consumption: 5V, 0.07A; 24V, --.
Standards: UC1, CE.
It transmits 16 points of I/O signals per,
word with a pair of cables.
Easy and minimized wiring effort,
The B7A Interface Unit and B7A Link Terminal,
can be used in the same way as a standard,
Basic I/O Unit and I/O Terminal without,
any need to worry about communications.
This characteristic reduces the wiring,
when using more than one relatively remote,
sensor or actuator. Unit classification: CJ1 CPU Bus Unit.
Specifications:Equipped with Master,
and Slave functtionality CJ1W-DA021.
Controls for up to 32,000 points per Master.
Communications:Remote I/O Communications,
Master (fixed allocations or user-set,
allocations) Remote I/O Communications,
Slave (fixed allocations or user-set,
allocations) Messsage communica29A; 24V,-- CJ1W-DA021.
Smallest in the Industry!
A DeviceNet Unit for the,
CJ Series that Boasts Industry-leading,
Performance and Functions.