UM: 31.2K words.
DM: 6K words.
EM: 6Kx3 banks(18K) words.
Instruction processing time (basic instructions): 0.1 µ.s min.
No. of I/O points: 880 points.
Max. no.of con-necting Expansion I/O Racks: 2 Racks.
Max. no. of connecting High-density I/O Units(i.e., Group-2): Unavailable.
Max. no. of con-necting Special I/O Units: 10.
UM: 15.2K words.
DM: 6K words.
EM: 6K words.
Instruction processing time (basic instructions): 0.15 µ.s min.
No. of I/O points: 880 points.
Max. no.of connecting Expansion I/O Racks: 2 Racks.
Max. no. of connecting High-density I/O Units(i.e., Group-2): Unavailable.
Max. no. of con-necting Special I/O Units: 10 C200HX-CPU34-ZE.
RS-232C: NO.Capacity: 16K word.
Access time: 150ns.
When using SYSMAC-CPT, can not be written in EPROM
C200HX-CPU34-ZE
To write a program to the EPROM, use the standard PROM writer.
Before the EPPROM memory card into the CPU, to connect the EPROM to the EPROM memory card.
If you remove the EPROM memory card from the CPU,
Will not lose its data.Name: Heat/Cool Temperature Control Module.
Model: C200H-TV002 C200HX-CPU34-ZE.
Sensor: Thermocouple: R, S, K, J, T, E, B, N, L, U.
Control output: Voltage output(transistor output used for cooling outputs).Name: Heat/Cool Temperature Control Module.
Model: C200H-TV101.
Sensor: Platinum resistance thermometer: JPt100, Pt100.
Control output: Transistor output.ASCII Unit
This program runs independently from the ladder-diagram program in the PLC.
Name: ASCII Module C200HX-CPU34-ZE.
Model: C200H-ASC02.
ASCII/BASIC Module Utility Software: For AT-compatible computers. enables program development, downloading, uploading, etc.Name: Space Module.
Model: C200H-BAT09.
Description: Replacement for memoryModel: C200H-ID501.
No. of inputs: 32 pts.
Specifications: 5 VDC.Model: C200H-ID211.
No. of inputs: 8 pts.
Input voltage: 12 to 24 VDC, +10%/–15%.
Input current: 10mA, 24VDC.
Isolation: Photo-coupler.
Indica-tor: LED.
External connec-tions: Remove-able termi-nal blocks.
Inputs percom-mon: 8 pts.
Internal currentcon-sump-tion: 10mConnects Power Supply Adapter and SYSMAC NET Link Unit.
For 1 Unit.Model: C200HW-BI0051 C200HX-CPU34-ZE.
No. of I/O slots: 5 slots.Model: C200H-TS002.
Temperature sensor: Thermocou-ples: K (CA)/L (Fe-CuNi)(DIN)(selectable)
Input points: 4 points/Unit max. (1, 2, or 4 points can be selected)Name: Position Control Module.
Model: CC200H-NC112 C200HX-CPU34-ZE.
Control method: Open-loop, automatic trapezoid acceleration/deceleration.
Control output sig-nals: Pulse-train outputs.
Controlled axes: 1.