Fitting materials: Stainless steel (SUS304).
Count: 1 .
Accessories: Description, --;
Material, --;
Count, --.
Applicable sensor (mounting pitch on sensor side): E3T-F (8).
Page: Dimensions, 12. Contact type: Standard load (250 VAC, 2 A; 125 VDC 0.4 A).
Operation: Alternate operation (Self-holding).
Output: DPDT.
Lighting: LED, 24 VDC.
Operation Unit color symbol: Enter the desired color symbol for the,
Pushbutton in @@
E3X-DA11AT-S 2M R (Red); Y (Yellow); G (Green); A (Blue); W (White).
Pushbutton Switch Series with.
Square 40-mm Body.
Combines miniature design with distinct but soft sense of operation.
Easy panel mounting from the front and simple lamp replacement.
without tools. Number of beams: 45.
Protective height: 1120mm.
Model: NPN output.
Basic Type with a combination of.
performance and functionality.
Up to three sets of series-connected sensors.
The muting function is enabled simply with Muting Key Cap.
Comes standard with interlock and auxiliary output functions. Output configuration: DC switching NPN (normally open or closed selectable).
Sensing method: Reflective; Convergent reflective (Distance adjustable).
Sensing distance: 5 to 20 cm.
Capable of Setting the Sensing Range.
Using an Ultrasonic Beam.
Ensures the stable detection of a variety of objects,
regardless of the color, transparency, or material.
(metallic or non-metallic) of the objects.
Limits the ultrasonic beam width to 8°, thus,
detecting minute objects as small as 2 x 2 cm.
Detects objects smoothly while largely suppressing,
interference from background objects.
Sealed to resist dust and dirt and emits ultrasonic,
waves at a frequency of approximately 200 kHz,
thus providing high immunity from impact and,
environmental noise. Models: OVGR (64).
Protection of distributed power supply connection to power system,
The relay is smaller, and the protection unit is more enriched.
Waste heat generation system improve the comprehensive energy efficiency and the use of natural,
Energy of wind power generation, the spread of power is becoming more and more popular.
This relay is used to detect the internal fault of the user in the distributed power supply,
Power line accident of distributed power supply and relay protection system.
The relay can be meet in Japan (system connected instant points specified in the standard model),
Function, can be through more than 20 kinds of products to establish the best protection system.
Can also correspond to the generator and the electric side / internal tributaries.
Unit with 2 relay elements.
In each unit, the variable action time circuit is hidden, so that the coordination design is more convenient.
All aircraft equipped with a locking relay terminal.
DSR can correctly determine the direction of the sudden drop in the voltage to 0 of the short-circuit accident.
2 stage cross terminal stand with cover with convenient wiring.
E3X-DA11AT-S 2M Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=E3X-DA11AT-S 2M&select=5