Type: PCB substrate with four socket connector.
Contact number: 4.
Wiring simple and e-CON * specifications for connectors;
Ideal choice for connecting sensors.
The connection of the spring clip which is verified by the industry is adopted.
Wiring is simple, no special tools required,
Can be re wiring (maintenance).
Acceptable range for each connector
Stranded AWG28 (0.08mm2) ~ AWG20 (0.5mm2),
Any core wire size between
E2E-X7D1S-M1
(outer diameter: no more than 1.5mm).
A clamp capable of simultaneously connecting 4 lines when a connection is also provided.
UL standard (Document No. E103202) identified as a standard product.
Cable connector with the UL standard certification of products.
"
Output: SPDT.
Lighting: LED (with built-in reduced-voltage lighting function).
Operating voltage: 100/110 VAC/VDC.
Pushbutton colorsymbol: R: red, Y: yellow; PY: pure yellow
G: green, A: blue; W: white; PW: pure white.
Item: Alternate operation (Self-holding).
Separate Construction with.
Cylindrical 16-dia. Body.
Miniature design of 28.5 mm, the smallest class in the industry.
Detachable Switch.
The same contacts can be used for both standard loads and microloads.
Easy-to-wire terminal arrangement.
Certified for EN 60947-5-1. Size: 96 x 96mm.
Ontology: terminal type, temperature input type.
Type: control output 1 point type (power AC/DC24V).
Shell color: black.
Control output: voltage output (SSR driver).
Control mode: standard or heating cooling.
Auxiliary output points: 3 points.
Heater with broken wire, SSR fault, heater over current detection function /ES1B power supply: single phase heater with detection function.
Event entry point: 2.
Transfer output: -.
Communication: -.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of /.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Increased the 3 segment display, which can display the current value / target / operation.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc., can be a key operation.
E2E-X7D1S-M1 Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=E2E-X7D1S-M1&select=5