Appearance: Square/Projection with Voltage Reduction Unit M22-C.
Lighting: LED.
Operating voltage: 100 VAC.
Illumination color: R (red); Y (yellow); G (green); W (white); A (blue).
Round Indicator Series with 22 dia. and.
25 dia. (when using a ring).
Same type as the A22-series Pushbutton Switches.
Use 25-dia. ring to install in 25-dia. panel cutouts.
IP65. Appearance: Rectangular (M16-A).
Lighting: Incandescent lamp, 12 VAC/VDC
D4NL-4FFG-B-NPT
Degree of protection: IP40.
Display color symbol: R: red; Y: yellow; G: green; A: blue;
W: white; PY: pure yellow; PW: pure white.
Cylindrical 16-dia. Indicator.
Same basic design as the A16 Pushbutton Switch. Optical system: Diffuse reflective.
Beam shape: Spot beam.
Sensing distance: 40±10 mm.
Resolution: 2 μm.
For the most recent information on models that have been,
certified for safety standards, refer to your OMRON website. Number of notches: 2 notches.
Output: DPDT.
Reset method: Manual.
Key release position: Right.
Separate Construction with Cylindrical.
16-dia. Body.
Short mounting depth, less than 28.5 mm below panel.
Wide range of switching capacity from standard to microload.
Oil-resistant IP65 models. C500-OD I/O Unit Transistor Output 64 pts C500-OD211(3G2A5-OD211).
DC24V 0.1A.E32-M21 type: special beam type; region detection,
Specialty: multi point detection (4 probe),
Shape / detection distance (mm): 750; 610; 350 (140),
Bending radius (mm): R25.
Standard test object (minimum test object) (mm) 1: 2 (0.1),
Fiber element for meeting diversified needsPower supply voltage: 100 to 240 VAC.
Heater control method: Phase control Cyclic control.
Input specifications: Two current inputs,
(for either single phase or threephase).
Output specifications: Two transistor outputs.
Communications output: RS-485.
Current input range: 0.200 to 2.200 A.
A high-precision Heater Element.
Burnout Detector compatible with a,
wide-range of heater control methods.
Push-in terminals reduce the workload.
Scaling.
NPN or PNP equivalent output.
Lineup includes models compatible with many heater control methods,
including ON/OFF control, phase control, and cyclic control.
High-precision heater burnout alarm with digital measurement.
Contributes to preventative maintenance.
If the gate function is disabled, the gate input can be used as an,
undercurrent/overcurrent relay or for motor or lamp loads.
Undercurrent detection values can be set separately for CT1 and CT2.
CE marking and cUL certified (K8AC-H2@@@).
D4NL-4FFG-B-NPT Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=D4NL-4FFG-B-NPT&select=5