Output: Contact.
Supply voltage: 100 to 240 VAC (50/60 Hz)/100 to 125 VDC;
24 to 48 VAC (50/60 Hz)/12 to 48 VDC.
Input type: No-input available.
Time range: 0.05 s to 300 h.
Operating mode(See note 2): Five multi-modes: A, B,B2, E, J (Power supply start).
Output: Transistor(Photocoupler).
Supply voltage: 24 to 48 VAC (50/60 Hz)/12 to 48 VDC.
Input type: No-voltage input.
Time range: 0.05 s to 300 h
D4NH-2ABC
Operating mode (See note 2): Eight multi-modes: A, B, B2, C, D, E, G, J.
Multiple Operating Modes and Multiple Time.
Ranges. DIN 48 x 48-mm Multifunctional Timer.
A wide AC/DC power supply range greatly reduces the number,
of timer models kept in stock.
A wide range of applications with multiple operating modes,
eight modes for 11-pin models and five modes for 8-pin models.
Ecological design with reduced current consumption.
Easy sequence checking with instantaneous outputs for a zero set value.
Length of 75 mm or less when panel-mounted with a P3G-08,
Socket (H3CR-A8E, 100 to 240 VAC, 100 to 125 VDC),
PNP input models available.
Standards: UL, CSA, NK, LR, CCC, EN 61812-1, and CE Marking. Sensing method: Diffuse-reflective Sensors.
Appearance: Vertical.
Connection method: Pre-wired.
Sensing distance: 100 mm (wide view).
Functions: Timer Self Diagnosis.
Model: PNP output.
Ordering Information.
Built-in Amplifier Photoelectric Sensors. Shape of box: With flange.
Actuator: Bevel plunger.
Conduit: Two on the side.
A New Monoblock Multiple Limit Switch.
Incorporating a Head Box with a Tough.
Head and Ensuring High Sealing.
Performance and a Mechanical.
Durability of 5,000,000 Operations.
Used for the sequential control of a variety of engineering.
machines and belt conveyor lines.
Built-in oil filter shuts out oil and water.
Approved by EN, IEC (Ground terminal models only.) and,
CCC (Chinese standard). Ask your OMRON representative,
for information on approved models.
Ground terminal models bear the CE mark. Analog I/O terminal with screw terminal,
block for EtherCAT communicaitons.
The input/output range can be easily,
changed by the setting with the switch.
Detachable screw terminal block,
facilitates the maintenance.
Moving average calculation function.
Settings within the range of 100μs-64ms.
(For input only.)
Disconnection detection function.
(For input only and for usage with,
1-5V or 4-20mA ranges.)
Selectable node address setting methods:
setting with rotary,
switch and with tool software.
When setting the nodes with rotary switch,
setting is easy and node identification,
becomes possible for maintenance.
D4NH-2ABC Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=D4NH-2ABC&select=5