Output type: Transistor sinking.
Inputs points: 24 points.
Outputs points: 16 points.Type: Ultra-long-term APC models.
Connecting method: Pre-wired (2 m).
Model: NPN output.
Applicable wire-saving connector(sold separately): Type,--; Model,--.
Stable Detection with Advanced Fiber.
Amplifier Units.
A wide range of added value with standard models with one,
input and two outputs, and ultra-long-term APC models with an,
APC life of approximately 20 years
D3V-65M-1C4
Power turning to easily set the optimum light level.
Automatic Power Control (APC) is always enabled to stabilize,
emitter power with high accuracy.
GIGA RAY for stable detection with the highest level of power in,
this class even for low-reflective objects and large objects.
The E3X-DA0-S supports an EtherCAT Sensor Communications,
Unit or CompoNet Sensor Communications Unit. Name: Safety I/O Terminals.
No. of I/O points: Safety inputs: 4, safety outputs (relay): 4, test outputs: 4.
Distributed Safety Terminals That.
Reduce Wiring.
Lineup includes four models to accommodate various,
I/O types and number of I/O points.
Monitor the safety system from Standard Controllers,
across the network.
EN954-1 (Cat.4), ISO13849-1 (PLe),
and IEC 61508 SIL3 certification.
The DST1-XD0808SL-1 also supports logic operation,
functions for high-speed processing in applications,
requiring partial stopping of the safety system. Size: 48 x 24mm.
Control output 1: voltage output (SSR driver).
Control output 2:--.
Auxiliary output: 2 points.
Power supply voltage: AC/DC24V.
Terminal type: screw terminal table type (with terminal cover).
Input category: full range multi input.
Heater disconnection, SSR fault detection function: 1 points.
Communication: -.
Event input: -.
A small body of 48 * 24mm specifications on the condensation operation, E5_C series of high performance.
Slender body width 48mm * 24mm * 90mm high depth,
The most suitable for small devices / physical and chemical equipment, etc..
Although the small size, but also through the character of the high 10.5mm white PV display to achieve high recognition.
The terminal stage is adopted to disassemble and assemble the structure, which improves the maintenance performance.
The connection method can be selected from a screw terminal and a PUSH-IN fastening terminal.
High speed sampling of 50ms is realized.
Easy to connect with PLC through no program communication.
The use of electric communication conversion Village (sold separately) connected to the computer after,
No power connection can be set.
It can be easily set by CS-Thermo (sold separately).
D3V-65M-1C4 Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=D3V-65M-1C4&select=5