Detects Objects in Multiple Directions,
with High Sensitivity, Ideal for Robotics,
Slow-action switching mechanism used.
Gold-plated contact with coil spring capable of switching,
micro current/voltage load while providing high contact reliability.
Inputs directly to microcomputers and programmable controllers.
Three sizes (M10, M8, and M5) and three types of compact actuators.
Easy panel mounting
D3M-01 Models: 3 UVR (27).
Protection of distributed power supply connection to power system,
The relay is smaller, and the protection unit is more enriched.
Waste heat generation system improve the comprehensive energy efficiency and the use of natural,
Energy of wind power generation, the spread of power is becoming more and more popular.
This relay is used to detect the internal fault of the user in the distributed power supply,
Power line accident of distributed power supply and relay protection system.
The relay can be meet in Japan (system connected instant points specified in the standard model),
Function, can be through more than 20 kinds of products to establish the best protection system.
Can also correspond to the generator and the electric side / internal tributaries.
Unit with 2 relay elements.
In each unit, the variable action time circuit is hidden, so that the coordination design is more convenient.
All aircraft equipped with a locking relay terminal.
DSR can correctly determine the direction of the sudden drop in the voltage to 0 of the short-circuit accident.
2 stage cross terminal stand with cover with convenient wiring. Rated primary current: 5 A.
Rated secondary current: Special output.
Installation: Installed separately.
High-performance Power Monitor Suitable for On-panel Mounting and Display.
Assists Energy-saving Analysis.
Energy classification for wasted standby and stopped power.
(Classification based on external inputs is also supported.)
Power and current can be measured simultaneously.
Measurement of flow rates with a pulse conversion function.
Simple temperature measurements with Temperature Sensor included in the Unit.
High-precision Measurements.
Measurement of generated power (regenerative power),
leading reactive power, lagging reactive power, and consumed power.
Power measurements on the primary side of inverters,
which are widely used to save energy.
Automatic range switching for accurate measurement of standby and stopped power.
Energy-saving Functions.
Conversion to monetary cost. (Also used for classified standby and stopped power.)
Alarm outputs can be selected for active power, reactive power,
regenerative power, current, voltage, or power factor.
The Power Monitor can log measurement data and supports Modbus communications.
Installation and Settings.
Direct measurement of three-phase, four-wire, 400-V line voltage.
Simple measurements without voltage wiring.
Incorrect voltage wiring detection.
D3M-01 Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=D3M-01&select=5