Actuator: Roller plunger.
Conduit size: 1-conduit; Pg13.5.
Built-in switch mechanism: 2NC (Slow-action).
Popular Safety Limit Switches.
Providing a Full Lineup Conforming to,
International Standards.
Lineup includes models with 1NC/1NO, 2NC, 2NC/1NO and,
3NC contact forms.
(Slow-action models with MBB contacts are available.)
M12-connector models are also available, saving on labor and,
simplifying replacement
G2R-1A-T DC24
Standardized gold-clad contacts provide high contact reliability.
Can be used with both standard loads and microloads.
Conforms to EN115-1, EN81-1, and EN81-2 (slow-action models only).
Certified standards: UL, EN (TÜV), and CCC. Actuator: Roller lever: R38.
Item: Basic.
Connector shape: Threaded (M12).
Built-in switch type: Airtight.
Voltage: AC.
Wiring locations: NO only 2 core.
Connector pin No: NO 3 4 .
Select the Best Two-circuit Switch for the,
Operating Environment and Application,
from a Wide Range of Models,
A wide selection of models is available, including General-purpose,
Environment-resistant, and Spatter prevention Switches.
Standard-feature gold-clad crossbar contacts provide high reliability.
Applicable to either standard loads or microloads.
Switches with Lever Actuators provide 90° overtravel,
one-side operation, and four-direction head mounting.
Approved standards: EN/IEC, UL, cUL, and CCC.
Contact your OMRON representative for information on approved models. Fitting materials: Iron, zinc plating.
Count: 2.
Accessories: Description, Phillips screws M3 × 10 Nuts M3;
Material, Iron, zinc plating Iron, zinc plating;
Count, 4, 4.
Applicable sensor (mounting pitch on sensor side): E32-T16P (19)E32-T16PR (19).
Page: Dimensions, 10. Improved update. Reduce standby power consumption, and then achieve lightweight.
Standby power consumption reduced to 85% of the company''s previous products. (61F-GN)
The quality is reduced to less than 85% of the company''s previous products. (61F-G3N, G4N)
With LED action display function, so that the state of action at a glance.
By improving the reliability of internal relays (tiny load 1mA DC5V), the PLC input becomes possible.
The electrode side terminals and other wiring terminals are separated, so the wiring operation is simple.
Installation method can choose the JEM agreement, DIN guide rail installation, screw installation in 3 ways.
Type: GN type, automatic water supply and drainage.
Package product name: 61F-GN base * 1, 61F-11_ unit * 1.
Purpose: long distance use (4km).