Appearance: Separate type.
Optical system: Through-beam.
Measuring width: 28mm.
Sensing distance: 0 to 500mm.
Resolution: 10µm.
Output type: NPN.
Measurable at any position.
The usual limitations, such as the ''measurement,
area being confined to the center''
or ''large errors due to positioning'',
that used to plague laser measuring sensors,
have now been overcome. Measurements can be,
consistently taken within a 500 mm area,
whatever stage the work is at or whichever way it is inserted
G2R-1 AC6
It can now be set to positions without interference from,
the work feed and without limitations of size of work area. Control terminal block: Screwless clamp terminal block.
Type: Standard.
Capacity: 20 A, 100 to 240 VAC.
Heater burnout detection: No.
Communications: No.
High-precision Control with Easy Setup,
Precise heater burnout detection.
Set value and present value monitoring with indicators.
Phase control or optimum cycle control.
RS-485 communications to set manipulated variables and,
monitor load current.
Total run time monitoring.
Output modes for phase control: proportional to phase angle,
proportional to voltage, proportional to square voltage,
and constant-current control.
Application with various loads: constant load resistance,
variable load resistance.
UL, and IEC/EN (TÜV) certified. Number of notches: 2 notches.
Output: SPDT.
Reset method: Automatic.
Key release position: Left.
Separate Construction with Cylindrical.
16-dia. Body.
Short mounting depth, less than 28.5 mm below panel.
Wide range of switching capacity from standard to microload.
Oil-resistant IP65 models. Release Key Type: Standard (metal).
Wiring method: Connector.
Solenoid voltage/Indicator: 24VDC (without indicator).
Lock and release type: Mechanical lock Solenoid release.
Contact configuration (door open/closed detection switch,
and lock monitor switch contacts): 4-contact Model,
Insert the built-in switch (A, B, C, D, S, T, U or V) into the blank @.
Conduit size (See Note.): 1/2-14NPT.
World''s smallest Class 6-contact Guard Lock.
Safety-door Switch.
.
Wiring time is reduced with two types of wiring.
methods capable of one-touch attachment and removal.
A wide variety of built-in switches can be used for various devices.
(4-, 5-, and 6-contact models are available).
Key holding force of 1,300 N.
It is possible to change the key insertion point.
without detaching the head.
Drive solenoids directly from the Controller.
.
Lockout Key to prevent workers from becoming.
trapped inside the hazardous area.
The vertical D4SL Guard Lock Safety-door Switch,
can be easily mounted on 40 × 40 mm aluminum frames.
The plastic material makes the Slide Key suitable,
for lightweight doors.
G2R-1 AC6 Operation manual/Instructions/Model selection sample download link: /searchDownload.html?Search=G2R-1 AC6&select=5