Size: 96 x 96mm.
Category: power AC100 ~ 240V with.
Shell color: black.
Control output 1: output unit mode.
Control output 2: output unit mode.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
The detection function of the broken wire and SSR fault of heater: detection function of single phase or three phase heater.
Event entry point: 2.
Transfer output: -.
Remote SP:4 to 20mA input
FZ4-L355-10
Communication: RS-485.
General thermostat new high performance (high resolution, high speed, high precision input) type products.
Support simple operation, preventive maintenance.
A new type of liquid crystal, which can communicate with the front through the infrared port, is adopted,
Visual angle, contrast can be improved.
High resolution 5 bit display / can display 0.01 degrees C.
High speed sampling period 60ms.
All models complete a variety of (to the thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors.
Also supports remote SP.
Add PV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactive display PV/SV.
By supporting software (Ver.4.0 CX-Thermo) to carry out a simple function (AND/OR logic and delay),
Be able to execute flexible contact output.
Increase the control output ON/OFF number counting function, can predict the temperature controller internal relay fault.
Position ratio type. Digital Rotary Pulse Meter Capable of 50 kHz Measurements.
Visual confirmation of judgement results through display colors that switch,
between red and green.
Measures High-speed Pulses at 50 kHz.
Provides high-speed pulse measurements up to 50 kHz of rotary encoder,
or ON/OFF pulse.
signals and can perform rotating measurement of high-speed rotating objects.
Note: No-voltage contacts of up to 30 Hz are supported.
Six Measurement Operations Including Rotation (rpm)/Circumferential,
Speed, Ratio, and Cumulative.
One Rotary Pulse Meter has 6 rotary pulse measurement functions to,
support a variety.
of pulse measurement applications. Select the best function for your,
application from the.
following: Rotation (rpm)/circumferential speed/instantaneous flowrate,
(value proportional to frequency), absolute ratio, error ratio, error,
flow rate ratio, and passing.
speed (value inversely proportional to frequency).
DeviceNet models added to the series.
FZ4-L355-10 Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=FZ4-L355-10&select=5