LK Automation Limited LK Automation Limited
Brand Sort: OMRON
Home >> Price
OMRON F3ZN-S0870N30-01 Price
No PHOTO
OMRON F3ZN-S0870N30-01
C200HS-CPU31-E CPU
High-Performance CIM Version, Built-in RS-232C Port
The C200HS-CPU31-E and C200HS-CPU33-E controller offers the same basic functionality as the C200HS-CPU01-E/CPU03 controllers.
This CPU may be used ineither SYSMAC NET and/or SYSMAC LINK communication systems.
The built-in RS-232C port supports the same communications as the C200HS-CPU21/CPU23.Actuator: Adjustable roller lever, form lock (metal lever, rubber roller) F3ZN-S0870N30-01
Conduit size: 2-conduit; M20.
Built-in switch mechanism: 1NC/1NO(Snap-action).
Popular Safety Limit Switches.
Providing a Full Lineup Conforming to,
International Standards.
Lineup includes models with 1NC/1NO, 2NC, 2NC/1NO and,
3NC contact forms.
(Slow-action models with MBB contacts are available.)
M12-connector models are also available, saving on labor and,
simplifying replacement.
Standardized gold-clad contacts provide high contact reliability.
Can be used with both standard loads and microloads.
Conforms to EN115-1, EN81-1, and EN81-2 (slow-action models only).
Certified standards: UL, EN (TÜV), and CCC. Case color: Black.
Control output: Relay output.
Control mode *1: Standard or heating/cooling.
No. of auxiliary outputs: 1.
Detection of heater burnout, SSR failure, and heater overcurrent: --.
No. of event inputs: --.
Transfer output *2: --.
Communi cations: --.
Previous model: Thermocouple input, E5GN-R1TC;
Resistance thermometer input, E5GN-R1P.
New 48 x 24-mm Basic Temperature,
Controller with Enhanced Functions and,
Performance. Improved Indication Accuracy,
and Preventive Maintenance Function.
Indication Accuracy.
Thermocouple input: ±0.3% of PV (previous models: ±0.5%),
Pt input: ±0.2% of PV (previous models: ±0.5%),
Analog input: ±0.2% FS (previous models: ±0.5%),
Models are available with screw terminal blocks or screwless,
clamp terminal blocks.
A PV/SV-status display function can be set to automatically alternate,
between displaying the status of the Temperature Controller (auto/
manual, RUN/STOP, and alarms) and the PV or SV.
Preventive maintenance for relays in the Temperature,
Controller using a Control Output ON/OFF Counter.
Switch the PV display between three colors.
Compatible with Support Software (CX-Thermo version 4.2 or higher).
Eleven-segment displays.
Models are available with one or two alarm outputs.
F3ZN-S0870N30-01 Operation manual/Instructions/Model selection sample download link: /searchDownload.html?Search=F3ZN-S0870N30-01&select=5


...more relevant model market price >>>>
Related products