LK Automation Limited LK Automation Limited
Brand Sort: OMRON
Home >> Price
OMRON F3SN-A0562P25-02 Price
No PHOTO
OMRON F3SN-A0562P25-02
Actuator: Roller lever (resin lever, resin roller).
Conduit size: 2-conduit; M20.
Built-in switch mechanism: 1NC/1NO (Slow-action).
Popular Safety Limit Switches.
Providing a Full Lineup Conforming to,
International Standards.
Lineup includes models with 1NC/1NO, 2NC, 2NC/1NO and,
3NC contact forms.
(Slow-action models with MBB contacts are available.)
M12-connector models are also available, saving on labor and,
simplifying replacement F3SN-A0562P25-02
Standardized gold-clad contacts provide high contact reliability.
Can be used with both standard loads and microloads.
Conforms to EN115-1, EN81-1, and EN81-2 (slow-action models only).
Certified standards: UL, EN (TÜV), and CCC. Name: Temperature Control Module.
Model: C200H-TC101.
Sensor: Platinum resistance thermometer: JPt100 Pt100.
Control output: Transistor output.Release Key Type: Special (resin).
Wiring method: Terminal block.
Solenoid voltage/Indicator: 24VDC (Orange).
Lock and release type: Solenoid lock Mechanical release.
Contact configuration (door open/closed detection switch,
and lock monitor switch contacts): 5-contact Model,
Insert the built-in switch (E, F, G or H) into the blank @.
Conduit size (See Note.): 1/2-14NPT.
World''s smallest Class 6-contact Guard Lock.
Safety-door Switch.
.
Wiring time is reduced with two types of wiring.
methods capable of one-touch attachment and removal.
A wide variety of built-in switches can be used for various devices.
(4-, 5-, and 6-contact models are available).
Key holding force of 1,300 N.
It is possible to change the key insertion point.
without detaching the head. Size: 1/16 DIN.
Case color: Black.
Power supply voltage: 24 VAC/VDC.
Input type: Thermocouple or resistance thermometer.
Auxiliary outputs: 2.
Control output 1: Relay output.
New 48 x 48-mm Basic Temperature.
Controller with Enhanced Functions and,
Performance. Improved Indication Accuracy,
and Preventive Maintenance Function.
Indication Accuracy.
Thermocouple input: ±0.3% of PV (previous models: ±0.5%),
Pt input: ±0.2% of PV (previous models: ±0.5%),
Analog input: ±0.2% FS (previous models: ±0.5%),
New E5CN-U Models (Plug-in Models) with analog inputs and,
current outputs.
A PV/SV-status display function can be set to automatically alternate,
between displaying the status of the Temperature Controller (auto/
manual, RUN/STOP, and alarms) and the PV or SV.
Preventive maintenance for relays in the Temperature,
Controller using a Control Output ON/OFF Counter.
F3SN-A0562P25-02 Operation manual/Instructions/Model selection sample download link: /searchDownload.html?Search=F3SN-A0562P25-02&select=5


...more relevant model market price >>>>
Related products