Sensing method: Through-beam type.
Sensing distance(slot width): 5 mm.
Output type: NPN output.
Output configuration: Dark-ON.
Cable length: 1 m.
Photomicrosensor with built-in,
amplifier and attached cable reduces,
external light interference.
Light modulation effectively reduces external light interference.
Wide operation voltage range: 5 to 24 VDC.
Easy operation monitoring with bright light indicator
F3SJ-E0545P25 Type: output module.
Insulation mode: three end two-way photoelectric switch.
Action indicator: there.
Zero crossing trigger function.
Applicable load of output: AC100 2A ~ 240V.
Input rated voltage: DC12V.
I/O solid state relay can be used for OMRON I/O type G7TC relay terminal.
Input and output composite input module, the output module is complete.
Can be used for I/O type P7TF terminal. Can also be mixed with the I/O type G7T relay.
Can check the working status of SSR through the action indicator.
Have access to UL, CSA standard certification of the series of products have also been series (-US type)Specifications: Inputs; NPN (+ common); 16 points.
I/O connections: M3 Screw terminals.
Rated internal circuit power supply voltage:
Supplied from the communications connector.
Rated I/O power supply voltage: 24 VDC.
Allows I/O Expansion with Transistor Terminals.
Wide variety of data, such as maintenance system data,
can be collected without affecting the productivity,
of the control system.
Valuable information can be collected,
and managed through the network, including information,
on the communications power supply.
voltage levels, Unit wear and tear,
and equipment operating information.
Expansion via Expansion I/O Units.
With no communications baud rate settings,
required and detachable terminal blocks,
maintenance is easier. Actuator: One-way roller arm lever (vertical).
Conduit size: 1-conduit; G1/2.
Built-in switch mechanism: 3NC (Slow-action).
Popular Safety Limit Switches.
Providing a Full Lineup Conforming to,
International Standards.
Lineup includes models with 1NC/1NO, 2NC, 2NC/1NO and,
3NC contact forms.
(Slow-action models with MBB contacts are available.)
M12-connector models are also available, saving on labor and,
simplifying replacement.
Standardized gold-clad contacts provide high contact reliability.
Can be used with both standard loads and microloads.
Conforms to EN115-1, EN81-1, and EN81-2 (slow-action models only).
Certified standards: UL, EN (TÜV), and CCC.
F3SJ-E0545P25 Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=F3SJ-E0545P25&select=5