LK Automation Limited LK Automation Limited
Brand Sort: OMRON
Home >> Price
OMRON F3SJ-A2117N14 Price
No PHOTO
OMRON F3SJ-A2117N14
Operation/resetting system: Time-limit operation/self-resetting.
Time-limit contact: DPDT (for power switching).
Time ranges: 0.04 s to 3 h.
Supply voltage: 24, 100 to 120, 200 to 230, 240 VAC (50/60 Hz);
12, 24, 48, 125, 100 to 110 VDC.
Mounting: Surface mounting (with PCB terminals).
Miniature Timer Compatible with the MY Relay.
Semi-multi power supply voltage.
Large transparent time setting knob facilitates time setting F3SJ-A2117N14
A flat-blade and Phillips screwdriver can also be used for time setting.
Pin configuration compatible with MY Power Relay.
LED indication for power and output statuses.
Conforms to EMC standards.
Conforms to EN 61812-1 and approved by UL and CSA. Power supply: DC.
Output type: PNP.
High-accuracy Detection of Metal Workpiece Displacement.
Sensor Heads support a wide variety of applications.
Linearity can be adjusted for non-ferrous metals,
such as SUS and aluminum, using the material selection function.
Simple linearity compensation (teaching).
Easily perform calculation for two Sensors by using a Calculating Unit.
Prevent mutual interference for up to five Units by using a Calculating Unit. Type: Multi-pole, Square Connector.
Terminal Block: Terminal block with M3.5 screws.
Connector: Multi-pole, Square Connector Plugs *2.
No. of poles: 50.
Simplifies Connector and terminal,
block replacement, and requires less,
in-panel wiring.
Mount to DIN Track or via screws.
MIL Flat Cable Connectors and Multi-pole, Square,
Connectors are standard.
Terminal blocks available with either M3 or M3.5 screws.
Connecting Cables for Programmable Controllers,
available (sold separately). Control power supply voltage: 48 VDC.
Input: DC, Input voltage range, 0.2 to 12 V.
Overvoltage/Undervoltage Monitoring.
Relay for AC and DC Input.
Detect overvoltages or undervoltages (switch select,
able) from 4 mV to 300 V.
Detect undercurrent, reverse current, or overcurrent in,
DC circuits using shunt (SDV-FL).
Detect three-phase AC current for under and/or overcur,
rent using current converter.
Available in 7 supply voltage configurations.
Single-function model with ON-delay, OFF-delay, or star,
tup lock settings (SDV-FH@T).
Select either AC or DC voltage input.
Polarity can be specified (SDV-FL) to enable easy re,
verse current detection.
Selectable reset value range from 2% to 30% of operat,
ing value (SDV-F).
LED operation indicator.
UL/CSA approval (SDV-F@).
F3SJ-A2117N14 Operation manual/Instructions/Model selection sample download link: /searchDownload.html?Search=F3SJ-A2117N14&select=5


...more relevant model market price >>>>
Related products
OMRON
Safety Light Curtain
F3SJ-A2370N55
OMRON Safety Light Curtain F3SJ-A2370N55
Numer of eams: 48. Protective height:
OMRON
Safety Light Curtain
F3SJ-A0470N30
OMRON Safety Light Curtain F3SJ-A0470N30
Numer of eams: 19. Protective height:
OMRON
Safety Light Curtain
F3SJ-A1570P55
OMRON Safety Light Curtain F3SJ-A1570P55
Numer of eams: 32. Protective height:
OMRON
Safety Light Curtain
F3SJ-A2495N30
OMRON Safety Light Curtain F3SJ-A2495N30
Numer of eams: 100. Protective height