Actuator: Roller lever R38.
Item: Anti-coolant; High-sensitivity.
Pretravel (PT): 10°.
Select the Best Two-circuit Switch for the,
Operating Environment and Application,
from a Wide Range of Models,
A wide selection of models is available, including General-purpose,
Environment-resistant, and Spatter prevention Switches.
Standard-feature gold-clad crossbar contacts provide high reliability
F3SJ-A1199N14
Applicable to either standard loads or microloads.
Switches with Lever Actuators provide 90° overtravel,
one-side operation, and four-direction head mounting.
Approved standards: EN/IEC, UL, cUL, and CCC.
Contact your OMRON representative for information on approved models. Supply voltage: 100 or 230 V AC (selectable), 50/60 Hz.
Operating voltage range: 85 to 265 V AC.
Output capacity: 5 V DC: 6 A 24 V DC: 0.5 A(30 W total, see note).Operating method: Incrementing and decrementing (selectable with DIP switch).
Mounting method: Flush mounting.
Operation modes: N, F, C, R, K, P, Q (selectable with rotary DIP switch).
Input signal method (Count and reset inputs): Contact and transistor input, voltage (H and L).
Control output: 1-stage counters: Contact (SPDT) and transistor,
output (H and L output switchable);
2-stage counters: Contact (SPST-NO) and transistor output,
(H and L output switchable).
Set value read: Continuous mode.
Memory backup: Yes/No (Selectable using DIP switch).
Display: Yes (10-mm high 7-segment LED, Up indicator).
Models: 2 digits; 1 stage.
A DIN 72 x 72 mm Best-selling Counter.
Easy setting with thumbwheel switches.
A draw-out construction enables maintenance without rewiring.
Models with 2-, 4-, 6-, or 8-digit displays are also available.
Total Counter models are also Available.
Complies with UL and CSA Marking. Unit type: CS1 Special I/O Units.
Product name: Isolated-type,
Resistance Thermocouple Input Units.
points Input: 4 inputs.
Signal range selection:
Set separately for each input.
I/O type: Pt100, JPt100.
Conversion speed (resolution):
250 ms/4 inputs.
Externa connection: Removable erminal block.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.25A; 26V, --.
Standards: UC1, CE.
Provides the functionality of isolators,
power supplies, signal converters,
and other devices.
The Analog Input Unit converts analog,
input signals such as 1 to 5 V or 4 to 20mA,
into digital values, and takes the values,
scaled in industrial units, and transfers,
it to the CPU Unit as the process value.
Because of this, no ladder program is required,
at the CPU Unit for scaling.
The Analog Output Unit converts analog output set,
values from the CPU Unit to analog output signals,
such as 4 to 20 mA or 1 to 5 V, and outputs them.
The built-in functions, such as measurement value,
alarms, rate-of-change calculations, and square roots,
have enabled major savings in cost and space compared,
with previous systems.
High-resolution Models and 8-point Input Models are,
also available.
By combining the Units, logging/monitoring.
systems can be constructed,
or the Units can be used together with LCBs/LCUs,
to construct complete process control systems.
Parameters can be easily displayed and set in an,
easy-to-understand form without special tools.
F3SJ-A1199N14 Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=F3SJ-A1199N14&select=5