Appearance: Round/Half-guard type A22-H.
Output: SPST-NC.
Operation: Momentary operation (self-resetting).
Illumination color: R (red); Y (yellow); G (green);
W (white); A (blue); B (black).
Install in 22-dia. or 25-dia. Panel Cutout.
(When Using a Ring).
Lever for easily mounting and removing the Switch Unit.
Increase wiring efficiency with three-row mounting of Switch Blocks.
Finger protection mechanism on Switch Unit provided as a standard feature
F39-HN0847-25
Use 25-dia. ring to install in 25-dia. panel cutouts.
Mounted using either open-type (fork-type) or closed-type.
(round-type) crimp terminals.
IP65 oil resistance (non-lighted models).
IP65 (lighted models). Size: 96 x 96mm.
Ontology: terminal type, temperature input type.
Category: control output 2 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output 1: current output.
Control output 2: high life relay output.
Control mode: standard or heating cooling.
Auxiliary output points: 3 points.
A power supply for the detection of /ES1B fault, SSR fault and heater over current for heater use.
Event input points: -.
Transfer output: output (using control output).
Communication: -.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of /.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Increased the 3 segment display, which can display the current value / target / operation.
Added PF keys to assign automatic / manual, RUN/Unit type: CJ1 CPU Bus Units.
Product Name: Serial Communications,
Units High-speed type.
Specifications:Communications Interface,
2 RS-422A/485 ports; Communications functions,
The following functions can be selected,
for each port with an CJ system:
Protocol macro, Host Link, NT Links (1:N mode),
Serial Gateway, No-protocol, Modbus-RTU Slave,
The following functions can be selected,
for each port with an NJ system: Protocol macro,
Serial Gateway, No-protocol, Modbus-RTU Slave.
No. of unit numbers allocated: 1.
Current consumption : 5V, 0.40A; 24V,--.
Standards: UC1, N, L, CE.
The Serial Communications Units That Enable,
High-speed Connections with External Devices.
Each Serial Communications Unit provides two,
serial communications ports: RS-232C and,
RS-422A/485, and the serial communications,
mode can be set separately for each port from,
Protocol Macro, Host Link, NT Link,
Serial Gateway, and No-protocol.
F39-HN0847-25 Operation manual/Instructions/Model selection sample download link: