Product: NT21 Programmable Terminal.
Specification: Monochrome STN, Frame color: beige.
Compact Size, High Performance.
Superb functionality with a compact screen size. Display type: DOWN display timer (decrements form the set time to 0).
Output type: Contact output (SPDT).
Pin type: 8-pin.
Memory backup: Not provided.
Supply voltage: 100 to 240 VAC, 12 to 48 VDC.
Rated time: 0.001 to 99.99 s
F2EL-X1R5F1-M3L
Miniature DIN-sized (48 x 48 mm) Quartz.
Timer with Abundant Series Versions.
Series version cover a wide range of rated times; 9.999 s,
99.99 s, 999.9 s, 99 min 59 s, and 99 hrs 59 min.
Selection of elapsed time indication, remaining time indication,
contact output, and transistor output types to suit requirements.
Power supply freely selectable within a range of 100 to,
240 VAC, as well as 12 to 48 VDC.
Certified for UL and CSA safety standards. Actuator: Adjustable roller lever, form lock (metal lever, resin roller).
Conduit size: 1-conduit; Pg13.5.
Built-in switch mechanism: 3NC (Slow-action).
Popular Safety Limit Switches.
Providing a Full Lineup Conforming to,
International Standards.
Lineup includes models with 1NC/1NO, 2NC, 2NC/1NO and,
3NC contact forms.
(Slow-action models with MBB contacts are available.)
M12-connector models are also available, saving on labor and,
simplifying replacement.
Standardized gold-clad contacts provide high contact reliability.
Can be used with both standard loads and microloads.
Conforms to EN115-1, EN81-1, and EN81-2 (slow-action models only).
Certified standards: UL, EN (TÜV), and CCC. Appearance: Shielded.
Sensing distance: 5 mm.
Output configuration: DC 3-wire, NPN.
Model: Operation mode, NO.
Standard Flat Sensors in.
Many Different Variations.
Only 6 mm thick yet provides a sensing,
distance of 3 mm (TL-W3MC1).
Aluminum die-cast models also available. Ontology: terminal type, analog input type.
Category: control output 2 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output 1: current output.
Control output 2: voltage output (SSR driver).
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
A power supply for the detection of /ES1B fault, SSR fault and heater over current for heater use.
Event entry point: 2.
Transfer output: output (using control output).
Communication: -.
48mm general thermostat has been upgraded & function / performance upgrade.
Indicates that the accuracy is increased and the preventive maintenance function is increased,
Further performance improvement.
E5CN-U (insert type) add analog input and current output type.
Add PV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactive display PV/SV.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
F2EL-X1R5F1-M3L Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=F2EL-X1R5F1-M3L&select=5