LK Automation Limited LK Automation Limited
Brand Sort: OMRON
Home >> Price
OMRON E2FM-X5D1-M1TGJ-T 0.3M Price
OMRON E2FM-X5D1-M1TGJ-T 0.3M
Safety outputs *3: Instantaneous, 3(Semiconductor);
OFF-delayed*2, 2 (Semiconductor).
Auxiliary outputs *4: 2(Semiconductor).
Logical AND connection: Inputs, 1(Semiconductor); Outputs, 1(Semiconductor).
No. of input channels: 1 or 2 channels.
Max. OFF-delay time *1: 150 s.
Rated voltage: 24 VDC.
Terminal block type: Screw terminals.
Logical AND Function Adds Flexibility to I/O Expansion.
Facilitates partial or complete control system setup E2FM-X5D1-M1TGJ-T 0.3M
Solid-state outputs (excluding Expansion Units).
Detailed LED indications enable easy diagnosis.
TÜV SÜD certification for compliance,
with IEC/EN61508 (SIL3), EN ISO13849-1 (PLe/Safety Category 4).
Approved by UL and CSA.
New unit joins the Series with the following two additional features:
-OFF-delay time of up to 150 seconds can be set.
-Two logical AND connection inputs. Sensing method: Through-beam type.
Sensing distance: 300 mm.
Output type: NPN output.
Output configuration: Light-ON.
Cable length: 2 m.
Cable length from emitter to amplifier: 0.5 m.
Compact, Thin-profile.
Photomicrosensor with special amplifier.
Slim amplifier (50 × 7.5 × 12 mm) can be handled like a cable.
Provided with two operation indicators, enabling monitoring from the,
amplifier housing and sensor head.
Simple wiring with a 3-conductor cable.
Wide operating voltage range: 12 to 24 VDC. Size: 96 x 96mm.
Ontology: terminal type, temperature input type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output: relay output.
Control mode: standard or heating cooling.
Auxiliary output points: 1 points.
A power supply for the detection of /ES1B fault, SSR fault and heater over current for heater use.
Event input points: -.
Transfer output: -.
Communication: -.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of /.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Increased the 3 segment display, which can display the current value / target / operation.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc., can be a key operation.
E2FM-X5D1-M1TGJ-T 0.3M Operation manual/Instructions/Model selection sample download link: /searchDownload.html?Search=E2FM-X5D1-M1TGJ-T 0.3M&select=5


...more relevant model market price >>>>
Related products